Quest Engineering Dry RDS 10 - User Manual

Quest Engineering Dry RDS 10
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
quest
quest
Quest DRY 150Quest Dry RDS 10
Installation, Operation and Maintenance InstructionsInstallation, Operation and Maintenance Instructions
– Read and Save These Instructions –
This manual is provided to acquaint you with
the dehumidier so that installation, operation
and maintenance can proceed successfully.
Ultimate satisfaction depends on the quality
of installation and a thorough understanding
of this equipment. The dehumidier is built
around tested engineering principles and has
passed a thorough inspection for quality of
workmanship and function.
4201 Lien Rd Phone 608-237-8400
Madison, WI 53704 Toll-Free 1-866-933-7476
www.QuestOnTheJob.com sales@QuestOnTheJob.com
– Read and Save These Instructions –
Specications subject to change without notice.
4037498
04/15
1
Quest Dry RDS 10:
Roto-mold design
80 pints per day at 80ºF/60%RH (AHAM)
(10 Gallons)
5.1 amps of power
12-inch recessed wheels
Telescoping handle
Solid state control panel
Multiple ducting options
Stackable design
• Lightweight
Water Removal Rate (Pints/Day)
80 pints 80˚F, 60% (AHAM)
quest
quest
Patent 7,246,503

Questions and Answers

  • P
    Paul DawsonAug 8, 2025
    Why is my Quest Engineering Dry RDS 10 not removing enough water?
    • L
      Lee JohnsonAug 8, 2025
      If the Quest Engineering Other unit isn't removing as much water as you'd expect, it could be due to several reasons. The air temperature or humidity might have dropped. The humidity meter or thermometer you're using could be out of calibration. The unit might be in a defrost cycle. A dirty air filter, a defective defrost thermistor, or a low refrigerant charge could also be the cause. Check for air leaks, such as a loose cover, or consider the possibility of a defective compressor. Finally, restrictive exhaust or inlet ducting could be the culprit.
  • K
    Karen HuynhAug 12, 2025
    Why does the compressor run when POWER is OFF on my Quest Engineering Dry RDS 10?
    • H
      Herbert CarterAug 12, 2025
      If your Quest Engineering Other unit's compressor runs even when the POWER button is OFF, it might be due to a defective relay or a defective control board. Another potential cause is if the upper housing is not sealed to the tower.
  • J
    Jeffrey LopezAug 16, 2025
    What to do if Quest Engineering Dry RDS 10 air mover runs but compressor doesn't?
    • T
      tjohnsonAug 16, 2025
      If your Quest Engineering Other unit is not dehumidifying, and the air mover runs but the compressor does not, consider the following: There might be a bad connection in the compressor circuit. The safety float switch might be closed, so check the pump reservoir. Other potential causes include a defective compressor capacitor, a defective compressor overload, or a defective compressor. Finally, the control board could be defective.
  • J
    Jacob MooneyAug 20, 2025
    Why is the evaporator coil frosted on my Quest Engineering Dry RDS 10?
    • D
      Dr. Regina RobinsonAug 20, 2025
      If your Quest Engineering Other unit shows continuous evaporator coil frosting and low dehumidifying capacity, the defrost thermistor might be loose or defective. It could also indicate a low refrigerant charge, a dirty air filter or restricted airflow, or that the upper housing isn't sealed to the lower housing.
  • E
    ewalkerAug 25, 2025
    Why does Quest Engineering Dry RDS 10 Other compressor run sporadically?
    • D
      denise36Aug 26, 2025
      If your Quest Engineering Other unit isn't dehumidifying, and the air mover runs continuously but the compressor only runs sporadically, it could be because the unit is in a defrost cycle, indicated by the DEFROST light being on. Alternatively, the defrost thermistor might be defective or loose, or there could be a loose connection in the compressor circuit. Other possible causes include a defective compressor overload, a defective compressor, a defective relay, or that the upper housing is not sealed to the lower housing.
  • J
    James JohnsonAug 29, 2025
    What to do if PURGE button doesn't work on Quest Engineering Dry RDS 10 Other?
    • R
      Richard AliAug 29, 2025
      If your Quest Engineering Other unit pumps water automatically but not when the PURGE button is pushed, there may be a bad connection in the PURGE button circuit or a defective control board.
  • V
    veronicarodriguezSep 2, 2025
    How to fix Quest Engineering Dry RDS 10 Other that won't turn on?
    • R
      Richard BrownSep 2, 2025
      If your Quest Engineering Other unit isn't dehumidifying, the hour meter display isn't working, the compressor isn't running, and the POWER button doesn't turn ON, first ensure the unit is plugged in and that the outlet has power. If that's not the issue, a defective control board or a loose connection in the internal wiring could be the cause.