21
TCD1022 D/1042 D - REV004A
GB
Note:
There is a delay of 2 seconds if the thruster is activated in one direction and then immediately activated in the
opposite direction (immediate movement from right to left or vice versa).
DISABLEMENT OF CONTROL PANEL
The control panel is disabled in the following cases:
When the enablement button is pressed.
When there are several controls in parallel and another is activated.
• If the direction buttons (TCD 1022) are not pressed or the joystick (TCD 1042) is not moved for 6 minutes.
Passage to the disabled state is signalled from the control with a prolonged sound of around one second and the
following slow fl ashing of the enablement leds.
The direction buttons (TCD1022) or the joystick (TCD 1042) are disabled.
MULTIPLE CONTROLS IN PARALLEL
Several TCD series control instruments can be installed in parallel. In this case, only one control panel can func-
tion at a time. The active control panel is always the last one to be activated; the other in parallel are automati-
cally disabled. If a command is sent to the thruster by the last control panel enabled, the boat movement direc-
tion will be indicated by the relative led which will light up also on the other disabled controls.
Disablement/enablement of the sound of the control.
The acoustic signals emitted by the control can be disabled.
Carry out the following procedure:
• Remove power to the control.
• Keep the enablement key pressed and supply power to the control which will emit a short sound.
• Release the enablement key and wait for the control to perform the testing of the LEDs and for it to be disabled
(slow fl ashing of the enablement LEDs).
The acoustic signals emitted by the control can be re-enabled.
Carry out the following procedure:
• Remove power to the control.
• Keep the enablement key pressed and supply power to the control which will emit two short sounds.
• Release the enablement key and wait for the control to perform the testing of the LEDs and for it to be disabled
(slow fl ashing of the enablement LEDs).