1.3 Benefits
1.4 System Venting Requirements
VERY IMPORTANT - Be sure to install enough inlet and outlet venting as described in the
following table:
Fan Model Required Inlet Venting* Required Outlet Venting** Airflow
AFG CON-3.0 4 SQ. FT. 4 SQ. FT. 3013 CFM
AFG ES-1500 2 SQ. FT. 2 SQ. FT. 1560 CFM
GA ES-1500 2 SQ. FT. 2 SQ. FT. 1452 CFM
GX ES-1100 1.5 SQ. FT.
N/A
(Exhausts Directly to Outside)
1103 CFM
RM ES-1100 1.5 SQ. FT.
N/A
(Exhausts Directly to Outside)
1130 CFM
RM ES-2200 3 SQ. FT.
N/A
(Exhausts Directly to Outside)
2245 CFM
* Inlet Venting includes openings such as windows, door, gable vents, ridge vents, eaves vents, etc. to allow air
to be pulled from the outside.
** Outlet Venting includes openings such as gable vents, ridge vents, eaves vents, etc. to allow air to be
exhausted from the attic.