Section II - QCS100
QCS100 Maintenance
Preparing for Maintenance
Shut off condensate inlet and switch
off compressor if necessary.
Inspect hoses and hose connections
regularly.
Weekly wastewater test:
Fill test tube at the sample valve.
Compare the test tube sample
cloudiness with the reference jar.
If the sample is clearer than the
reference jar the filter is okay (Figure
1).
If the sample is cloudier than the
reference jar the filter needs to be
changed (Figure 2).
notiCe
Never pour any foreign liquid into
the pressure relief chamber. This can
impair the filter efficiency.
FIGURE 1 FIGURE 2
Quincy Compressor-QCS High Efficiency Emulsion Separators 9