11 Pressure equipment directives
Components subject to 2014/68/EU Pressure Equipment Directive
The following table contains the necessary information for the inspection of all pressure
equipment of category II and higher according to the Pressure Equipment Directive 2014/68/EU
and all pressure equipment according to the Simple Pressure Vessel Directive 2014/29/EU.
Compressor
type
Component Description Volume Design
pressure
Minimum and
maximum
design
temperature
PED
Class
30-45 kW 1625 430224 Vessel 30 l 15 bar(e) -10 ˚C/ 120 ˚C II
0830 101068 Safety valve - - - IV
0830 101069 Safety valve - - - IV
Compressor type Component Description Number
of cycles
(1)
Minimum
wall
thickness
Inspection
frequency (2)
30-45 kW 1625 5641 99 Vessel
2 x 10
6
8 mm 10 years
0830 1010 68 Safety valve - - -
0830 1010 69 Safety valve - - -
The compressors conform to PED smaller than category II.
(1) The number of cycles refers to the number of cycles from 0 bar(e) to maximum pressure.
(2) The minimum wall thickness must be respected at all times. Inspection techniques such as
ultrasonic or X-ray are equivalent to hydrostatic testing for this equipment.
Instruction book
108 2920 7190 02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quincy Compressor QGD 60 and is the answer not in the manual?

Quincy Compressor QGD 60 Specifications

General IconGeneral
BrandQuincy Compressor
ModelQGD 60
CategoryAir Compressor
LanguageEnglish

Related product manuals