Read Operating Instructions thoroughly prior to operation. Use only a grounded outlet that is rated for
your models' electrical requirement. Conduct periodic maintenance as required. CAUTION:
EXPOSED ELEMENT - Operate unit well away from flammable solvents, gasses and materials.
Operate on non-combustible surface only.
Read Operating Instructions Thoroughly Prior to Operation
Safety Precautions
PAGE 1
Issue Rev A 0908
Quincy Lab Inc. 1925 N. Leamington Ave. Chicago, Illinois 60639 1-800-482-HEAT (4328)
Copyright Quincy Lab Inc. 2008
Model Series 160
Plastic Forming Strip Heaters
OPERATING MANUAL
Quincy Lab, Inc.
Overall Dimensions
INCHES W x H x D
(CM) W x H x D
15.125x5.5x7.25 25x5.5x7.25
36x5.5x7.25
Weight (lbs)
SHIPPING
STAND ALONE
7 lbs
6 lbs
9 lbs
7 3/4 lbs
12 lbs
10 1/2 lbs
Standard Electrical*
38.45x14x18.4 63.5x14x18.4 91.4x14x18.4
Specifications
MODEL
03-160
MODEL
13-160
MODEL
23-160
Working Area
Common Unit Construction
Exterior: Powder-Coated Steel Plug/Cord Assy: UL SJOW 18/3
Power Controls: On/Off Toggle & Power Light Heater: Resistive-Tubular Incoloy
VOLTS / WATTS
115 / 125
115 / 200
115 / 350
* Working Max Operating
Temperature Range (F)
325
o
/ 410
o
340
o
/ 435
o
AUTION
A U T I O N
URFACE MAY BE HOT
CAUTION
C A U T I O N
WORK SURFACE MAY BE HOT
12"
21"
33"
AMPS
1.08
1.72
3.02
After unpacking, verify receipt of correct quantities of each component and that each component has
not suffered any shipping damage. If there are any problems, please refer to the enclosed
Damaged/Missing Item Report.
Receiving
MODEL
03-160
SHOWN
CAUTION
AND EXPOSED ELEMENT
C A U T I O N
HOT SURFACES
* Measured with workpiece in place - (varies with piece size and length).
325
o
/ 410
o
Question and Answer IconNeed help?

Do you have a question about the Quincy lab 160 Series and is the answer not in the manual?

Quincy lab 160 Series Specifications

General IconGeneral
BrandQuincy lab
Model160 Series
CategoryHeater
LanguageEnglish

Summary

Product Specifications

Overall Dimensions

Details the width, height, and depth of the units in inches and centimeters.

Working Area and Weight

Specifies working area dimensions and shipping/stand-alone weight for each model.

Electrical Ratings

Provides voltage, wattage, and amperage ratings for each model.

Operating Temperature Range

Lists the maximum operating temperature ranges for the heaters.

Unit Construction and Safety

Construction Components

Details exterior material, power controls, cord assembly, and heater type.

General Safety Precautions

Important safety instructions regarding grounding, maintenance, and avoiding flammable materials.

Receiving and Setup

Receiving Instructions

Guidance on verifying component quantities and checking for shipping damage.

Initial Setup Steps

Instructions for positioning the unit, attaching feet, and plugging in.

Operation and Maintenance

General Operation Guide

Steps for placing and heating plastic workpieces for forming.

Maintenance Procedures

Instructions for cleaning the unit and heating element area.

Support and Warranty

Technical Support Contact

Provides phone, fax, and email details for customer support.

Replacement Parts

Lists available replacement components and their part numbers for specific models.

Limited Warranty Information

Details the warranty period, coverage for defects, and labor terms.