Parts/Instruction Manual
This manual contains important safety information and should be made available to
all personnel who operate and/or maintain this product. Carefully read this manual
before attempting to operate or perform maintenance on this equipment.
Manual No. 65504-2A
January 2007 Edition
Update: May 2009

Questions and Answers

  • J
    Joseph CruzAug 5, 2025
    What to do if my Quincy QPNC 75 motor cuts out on overload?
    • H
      hollywoodwardAug 5, 2025
      If the motor cuts out on overload, it could be due to several reasons. First, the dryer might be operating outside of its specified range; in this case, verify the treated air's flow rate. Secondly, the dryer might be working under unfavorable conditions for an air-cooled condenser; make sure to clean the condenser. Finally, the cooling circuit could be malfunctioning due to an incorrect refrigerant charge; check for any refrigerant gas leaks.
  • S
    sandra31Aug 9, 2025
    Why is my Quincy QPNC 75 compressor head so hot?
    • M
      Mathew JonesAug 9, 2025
      If the compressor head is very hot, exceeding 131 °F (55 °C), it could be due to a few reasons. The dryer might be operating outside its rated capacity, so check the flow rate of the treated air. Additionally, the dryer may be working under poor conditions for the air-cooled condenser, so you should clean the condenser. It's also possible that the cooling circuit isn't working correctly due to an incorrect refrigerant charge, in which case you should check for leaks of refrigerating gas.
  • L
    lowepamelaAug 13, 2025
    What to do if my Quincy QPNC 75 Dehumidifier compressor is very noisy?
    • C
      Christopher WashingtonAug 13, 2025
      If the compressor is very noisy, it indicates trouble with the internal mechanical parts or with the valves. You should consider repairing or replacing the affected components.
  • C
    Crystal CarterAug 17, 2025
    What to do if my Quincy QPNC 75 Dehumidifier motor hums and does not start?
    • K
      Kristy CallahanAug 17, 2025
      If the motor hums but doesn't start, it could be due to several reasons. First, the line voltage might be too low, in which case you should contact the electric power company. Second, the machine may have been switched off and on again too quickly, without allowing enough time for pressure balancing; wait a few minutes before restarting it. Lastly, the motor's starting system could be defective; check the running and starting relays and condensers, if installed.
  • S
    Sarah JonesAug 22, 2025
    What to do if my Quincy Dehumidifier machine stopped and does not restart?
    • C
      Christopher FergusonAug 22, 2025
      If the machine (compressor) has stopped and won't restart, it could be due to overload protection or a burned-out compressor motor. In the first case, refer to sections B2, B3, and C3 for remedies. In the second case, replace the compressor.
  • N
    Natalie BennettAug 27, 2025
    Why is there condensate in the pipings of my Quincy QPNC 75?
    • S
      Stephen ButlerAug 27, 2025
      The presence of condensate in the pipings may be due to several factors. The condensate separator might not be working correctly; in this case, clean the condensate drain filter. The dryer could be operating outside its specified range; check the flow rate of treated air. Also, the dryer might be working under bad conditions for the air-cooled condenser; make sure to clean the condenser.
  • J
    Jessica PenaAug 31, 2025
    How to fix a Quincy QPNC 75 with no compressed air passing through the outlet?
    • S
      Scott GonzalesAug 31, 2025
      If no compressed air passes through the dryer outlet, the pipes may be frozen inside. This could be because the hot gas bypass valve is broken or out of calibration, or because the room temperature is too low, causing the evaporator's piping to be obstructed with ice.

Summary

General Information

Safety Messages

Contains critical warnings and cautions regarding dryer use, fire risk, and proper application.

Safety Zones, Devices and Decals

Safety Risks

Identifies potential hazards present on the machine, including electrical voltage, air quality, pressure, and fan.

Safety Instructions

Read All Instructions Fully

Emphasizes the necessity of thoroughly reading and following all manual instructions before operation.

Installation Instructions

Electrical Connection

Instructions for verifying supply voltage and properly connecting the dryer to the power supply.

Connection to the Compressed Air System

Describes fitting a shut-off valve for isolating the dryer during maintenance operations.

Start-Up and Operation

Starting and Stopping

Procedure for safely starting and stopping the dryer in relation to the air compressor.

Controls

Operation

Explanation of the refrigerant cycle and the dryer's automatic operation via bypass valve.

Maintenance

Air Dryer Service Checklist

Troubleshooting

Presence of condensate in the pipings

Guidance on identifying and fixing causes for condensate appearing in the air piping system.

QPNC-75 (115 V) Wiring Diagram

QPNC-75 (230 V) Wiring Diagram

QPNC-100;125 (115 V) Wiring Diagram

QPNC-100;125 (230 V) Wiring Diagram

QPNC-150;175;200;250 Wiring Diagram

Quincy QPNC 75 Specifications

General IconGeneral
BrandQuincy
ModelQPNC 75
CategoryDehumidifier
LanguageEnglish

Related product manuals