Do you have a question about the QUNDIS water 5.5 and is the answer not in the manual?
Details the various display levels shown during a device error, including error codes, dates, and consumption data.
Explains error codes, leak detection indicators like 'LEAC', and the date of functional problems.
Provides a table mapping error codes to descriptions and recommended corrective actions or replacements.
Details cumulative volume, segment tests for display integrity, and the last recorded due date.
Shows consumption on the last due date, checksum calculation, and the device's radio mode.
Describes automatic activation of the radio transmitter and manual activation methods like IrDA or software.
Explains the 'walk-by' mode for mobile data recording, including control and regular telegram transmissions.
Details 'AMR' mode for automatic data recording, including installation, data, and statistics telegrams.
Lists parameter-setting possibilities via Q suite 5, such as display level control and leak detection thresholds.
Compares transmission behavior in C-mode and S-mode for AMR and walk-by data recording.
Provides specifications including norms, environmental conditions, energy supply, and battery details.
Details the various display levels shown during a device error, including error codes, dates, and consumption data.
Explains error codes, leak detection indicators like 'LEAC', and the date of functional problems.
Provides a table mapping error codes to descriptions and recommended corrective actions or replacements.
Details cumulative volume, segment tests for display integrity, and the last recorded due date.
Shows consumption on the last due date, checksum calculation, and the device's radio mode.
Describes automatic activation of the radio transmitter and manual activation methods like IrDA or software.
Explains the 'walk-by' mode for mobile data recording, including control and regular telegram transmissions.
Details 'AMR' mode for automatic data recording, including installation, data, and statistics telegrams.
Lists parameter-setting possibilities via Q suite 5, such as display level control and leak detection thresholds.
Compares transmission behavior in C-mode and S-mode for AMR and walk-by data recording.
Provides specifications including norms, environmental conditions, energy supply, and battery details.
| Maximum Operating Pressure | 16 bar |
|---|---|
| Installation Position | Horizontal or vertical |
| Resolution | 0.0001 m³ |
| Housing Material | Brass |
| Type | Water Meter |
| Nominal Flow Rate | 2.5 m³/h |
| Maximum Flow Rate | 5 m³/h |
| Maximum Operating Temperature | 90 °C |
| Meter Length | 110 mm |
| Thread Size | G 3/4" |
| Output | Pulse output |
| Power Supply | Battery |
| Operating Temperature | 0°C to 90°C |