Do you have a question about the R.M. Young 05103V and is the answer not in the manual?
Check for shipping damage, install propeller facing forward, and verify free rotation.
Formulas for converting sensor signals (RPM, mV) to engineering units (m/s, knots, mph).
Steps to replace a worn potentiometer due to noisy or non-linear signals.
| range | 200 to 15, 000 RPM in 100 RPM increments |
|---|---|
| rotation | Clockwise or Counter-Clockwise |
| display resolution | 1 RPM |
|---|---|
| quartz timebase reference | 0.1 RPM |
| power requirement | 2x9 V (alkaline or lithium) batteries |
|---|---|
| AC wall adapter | 115 VAC (230 VAC – add suffix H) |
| range | 20 to 990 RPM in 10 RPM increments |
|---|
| display resolution | 0.1 RPM |
|---|
| range | 0 to 360 degrees |
|---|
| resolution | 0.5 degree |
|---|
| range | 0 to 5.4 gm-cm |
|---|
| resolution | 0.1 gm-cm |
|---|
| range | 0 to 50 gm-cm |
|---|
| resolution | 5 gm-cm |
|---|