HSLED INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TROUBLESHOOTING
1. Check that the line voltage at xture is correct.
2. Is there voltage at the lamp xture wires? If there is no
voltage, check all connections.
3. Is the xture grounded properly?
4. If there is a photocell, is it working properly?
HSLED-IN-1212
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
1. Clean glass lens & xture with non-abrasive glass cleaning
solution.
2. Do not open xture to clean the LED. Do not touch the
LED.
3. Keep leaves and debris out of hood.
WIRING
Universal voltage driver permits operation at 120V through
277V, 50 or 60 Hz.
1. Connect the black xture lead to the (+) LINE supply lead.
2. Connect the white xture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from xture to supply ground.
HSLED13 HSLED13N HSLED13Y