EasyManua.ls Logo

Racepak Ultra Dash Xtreme - User Manual

Racepak Ultra Dash Xtreme
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Racepak
Ultra Dash
Installation and Operation Instructions
300-DS-UDX6S
Question and Answer IconNeed help?

Do you have a question about the Racepak Ultra Dash Xtreme and is the answer not in the manual?

Summary

Introduction

Six Button Dash Features

Lists the various features of the Ultra Dash display unit.

Package Contents

Lists all components included in the Ultra Dash kit.

Optional Items

Lists optional accessories available for the Ultra Dash system.

Ultra Dash Installation

Selecting a Mounting Location

Guidance on choosing an optimal position for the Ultra Dash unit.

Dash Mounting

Instructions for physically mounting the Ultra Dash unit.

Port Descriptions

Explains the function of each connector port on the Ultra Dash.

Port A Wiring

Details the pinout and wiring for Port A connector.

Port B Wiring

Details the pinout and wiring for Port B connector.

Sensor Installation

Instructions for installing various sensors like EGT and water temperature.

Jack Shaft Sensor and Collar Installation

Specific steps for installing the jack shaft sensor and collar.

Remote Switch

Explains the function and use of the remote switch.

External Battery

Instructions for connecting and using an external battery.

Installing V-Net Channels

Guide to adding expansion modules via the V-Net port.

Programming and Operation Using the Dash Buttons

How the Buttons Work

Explains button press types (SHORT, MED, LONG) and their functions.

Display Modes

Lists the different operational modes of the dash.

Setup Mode

Details how to enter and navigate the setup mode.

Setup Parameters

Lists and describes configurable parameters and their options.

Speedometer Calibration

Procedure for calibrating the speedometer reading.

Fuel Level Calibration

Procedure for calibrating the fuel level sensor.

Real-time Mode

Explains how the dash operates in real-time mode.

Scroll Mode

How to navigate and view different channels in scroll mode.

Min - Max Recall Mode

How to view minimum and maximum recorded values.

Record Mode

Instructions for entering and using the data recording function.

Playback Mode

How to review recorded data directly on the dash.

Warning Indicators

Explains the different types of warning indicators and their activation.

Clearing Alpha Display Warnings

Procedure for clearing active alpha display warnings.

Programming Using the DataLink PC Software

Installing the DataLink Software

Steps to install the DataLink software on a PC.

Installing the License Disk

Instructions for installing the software license disk.

Connecting the Data Logger Serial Communications Cable

How to connect the dash to the PC using the serial cable.

Modifying the Dash Configuration

Steps to change settings and configure the dash via PC software.

Device;Channel Editing

How to select and edit individual devices and channels in the software.

Channel Description Area

Explains the fields describing a selected channel.

Online Help Box

Describes the function of the online help text area.

Channel Scaling

How to enter calibration factors for sensors.

Graph Setup

How to define chart settings for data visualization.

Options List Box

Explains the list of user-settable options for devices.

Changing Dash Display Page Properties

How to customize the layout and variables on dash display pages.

Adding or Removing V-Net Devices to your System

How to update configuration files when V-Net devices are added or removed.

Configuring Record Parameters

Steps to set up data recording parameters like length and triggers.

Setting the Record Length

How to define the duration of data recordings.

Setting the Record Enable Channel

How to specify which channel triggers recording.

Setting the Record Start Threshold

How to set the value threshold for triggering recording.

Sending the Record Parameters

How to transfer the configured record parameters to the dash.

Transferring Data to a PC

Using the Serial Communications Port to Transfer Data to your PC

How to connect and transfer data using the serial port.

Naming and Storing the Run Data File

How to name and save transferred data files.

Viewing Real Time Data on a PC

Setting up the Real Time Telemetry Parameters

How to configure parameters for real-time data display.

Entering the DataLink Telemetry Parameters

How to set specific parameters for data logging.

Six Month Limited Warranty on Parts and Workmanship

Summary

Introduction

Six Button Dash Features

Lists the various features of the Ultra Dash display unit.

Package Contents

Lists all components included in the Ultra Dash kit.

Optional Items

Lists optional accessories available for the Ultra Dash system.

Ultra Dash Installation

Selecting a Mounting Location

Guidance on choosing an optimal position for the Ultra Dash unit.

Dash Mounting

Instructions for physically mounting the Ultra Dash unit.

Port Descriptions

Explains the function of each connector port on the Ultra Dash.

Port A Wiring

Details the pinout and wiring for Port A connector.

Port B Wiring

Details the pinout and wiring for Port B connector.

Sensor Installation

Instructions for installing various sensors like EGT and water temperature.

Jack Shaft Sensor and Collar Installation

Specific steps for installing the jack shaft sensor and collar.

Remote Switch

Explains the function and use of the remote switch.

External Battery

Instructions for connecting and using an external battery.

Installing V-Net Channels

Guide to adding expansion modules via the V-Net port.

Programming and Operation Using the Dash Buttons

How the Buttons Work

Explains button press types (SHORT, MED, LONG) and their functions.

Display Modes

Lists the different operational modes of the dash.

Setup Mode

Details how to enter and navigate the setup mode.

Setup Parameters

Lists and describes configurable parameters and their options.

Speedometer Calibration

Procedure for calibrating the speedometer reading.

Fuel Level Calibration

Procedure for calibrating the fuel level sensor.

Real-time Mode

Explains how the dash operates in real-time mode.

Scroll Mode

How to navigate and view different channels in scroll mode.

Min - Max Recall Mode

How to view minimum and maximum recorded values.

Record Mode

Instructions for entering and using the data recording function.

Playback Mode

How to review recorded data directly on the dash.

Warning Indicators

Explains the different types of warning indicators and their activation.

Clearing Alpha Display Warnings

Procedure for clearing active alpha display warnings.

Programming Using the DataLink PC Software

Installing the DataLink Software

Steps to install the DataLink software on a PC.

Installing the License Disk

Instructions for installing the software license disk.

Connecting the Data Logger Serial Communications Cable

How to connect the dash to the PC using the serial cable.

Modifying the Dash Configuration

Steps to change settings and configure the dash via PC software.

Device;Channel Editing

How to select and edit individual devices and channels in the software.

Channel Description Area

Explains the fields describing a selected channel.

Online Help Box

Describes the function of the online help text area.

Channel Scaling

How to enter calibration factors for sensors.

Graph Setup

How to define chart settings for data visualization.

Options List Box

Explains the list of user-settable options for devices.

Changing Dash Display Page Properties

How to customize the layout and variables on dash display pages.

Adding or Removing V-Net Devices to your System

How to update configuration files when V-Net devices are added or removed.

Configuring Record Parameters

Steps to set up data recording parameters like length and triggers.

Setting the Record Length

How to define the duration of data recordings.

Setting the Record Enable Channel

How to specify which channel triggers recording.

Setting the Record Start Threshold

How to set the value threshold for triggering recording.

Sending the Record Parameters

How to transfer the configured record parameters to the dash.

Transferring Data to a PC

Using the Serial Communications Port to Transfer Data to your PC

How to connect and transfer data using the serial port.

Naming and Storing the Run Data File

How to name and save transferred data files.

Viewing Real Time Data on a PC

Setting up the Real Time Telemetry Parameters

How to configure parameters for real-time data display.

Entering the DataLink Telemetry Parameters

How to set specific parameters for data logging.

Six Month Limited Warranty on Parts and Workmanship

Racepak Ultra Dash Xtreme Specifications

General IconGeneral
Data LoggingYes
USBYes
Display TypeLCD
GPSYes
InputsAnalog, Digital
CAN BusYes
CompatibilityRacepak
ConnectivityBluetooth

Related product manuals