Advanced Programming
Verbatim Owner's Manual
6-27
If you have turned the microphone on, as above, then during any phone call,
you may also invoke a one-time listening period by entering Remote Program
Mode (press 1 at the warble tone) and then entering 9 3 2 # #.
u To turn off the speaker so that neither alarm call or inquiry call activity is
heard at the unit, press:
9 34 0 ENTER
The speaker will still be heard when operating keys at the front panel.
u To turn the speaker on again, press:
9 34 1 ENTER
Note:
The speaker volume may be adjusted via the trimpot marked SPKR VOL
shown on the Electrical Connection Diagram. See Section A.1, "Adjusting
Internal Speaker Volume.
6.2.20 Program Clear Out Operations
The following list of program codes provides a flexible variety of operations to
conveniently clear selected programming items in order to allow for a fresh
start.
Code Function
935 0 Clears out phone numbers; sets all delays to default.
935 1 Clears out phone numbers only.
935 2 Clears out all alarm call grouping linkage.
935 3 Sets the following delays to their factory default values:
902, 903, 904, 920, 921, 926, 928
(921 sets power failure alarm ON)
935 4 Clears all user recorded messages.
935 5 Clears all programming except messages.
( Does not clear 913, 930, 941, and 942)
935 6 Clears all Totalizer counts to zero.
935 7 Clears and initializes clock.
935 9 Total clear out (Does not clear 941 and 942).
I Caution:
Code 9 35 9 erases all programming and messages.