Operating Instructions
Specifications
Temperature taking
Place the
Probe Cover
1. Proper installation of the probe cover ensures accurate
measurements.
2. Keep the probe covers away from children
1. Place the probe cover on the probe cover fixer(inside
of the storage box). Make sure to place the
Adhesive Side” of probe cover “Upward.”
Align the probe with the center of the probe cover.
2. Insert the probe into the probe cover fixer (in the
storage box) until you feel a “click”. That means the
probe cover has been connected firmly.
If the probe cover did not install well, will flash on
the LCD screen and can’t take the ear temperature (will
hear 4 beep sounds without reading shown on the LCD
when measuring).
Please check the setting of the probe cover again.
Power On
Press
“ON/MEM” button (on the left side)
See the icon on the LCD and hear two beep
sounds
Taking Ear
Temperature
Gently pull the ear back to straighten the ear canal and
snugly position the probe into the ear canal, aiming
towards the membrane of the eardrum to obtain an
accurate reading.
<For children under 2 years old>
Pull the ear straight back.
<For children over 2 years old and adults>
Pull the ear straight up and back.
Measuring
Press “Scan” button (on
the right side)
Press
the “Scan” button for 1 second until you hear a
long
beep sound. The measurement is completed. You
can read the result from LCD.
Fever Alarm:
If the thermometer detects a body temperature
37.5°C (99.5°F), three short beep sound
will follow
one long
beep sound to warn the user for potential fever.
Power Off Automatically shut down after 1 minute pending to extend battery life.
Attentions
a. The device must stay in stable ambient (room) temperature for 30 minutes before operating.
b.
Before the measurement, please stay in a stable environment for 5mins and avoid the exercise, bath for 30mins.
c. It is recommended that you measure the same ear for 3 times. If the 3 measurements are different, select the highest
temperature.
d. The thermometer has been designed for practical use. It’s not meant to replace a visit to the doctor. Please also remember
to compare the measurement result to your regular body temperature. Please consult with doctor if you have health
concerns.
Other Functions
Last Reading
After getting a new temperature reading, the last reading will be shown on the screen (at top right
corner) with the icon.
Memory
Locations
(25 sets)
When power on, Press the “ON/MEM” button to see the temperature records with icon.
°C / °F Switch
To change the LCD from °C to °F :
In “Power Off” mode, press and hold the “SCAN” button, then press the “ON/MEM” button for 3
seconds, icon “°C” will be switched to icon “°F”. You can also use the same process to change the
LCD display from °F to °C.
Temperature measurement range: 34~42.2°C (93.2~108°F)
Operating temperature range: 10~40°C (50~104°F)
Storage temperature range: It should be stored at room temperature between -20~+50°C , RH
85%
Transportation temperature shall be less than 70°C, RH
95%
Comply with ASTM E1965-98, EN12470-5:2003 Clinical thermometers-Part 5:Performance of infra-red ear thermometers
(with maximum device), IEC/EN60601-1-2(EMC), IEC/EN60601-1(Safety) standards.
Accuracy: +/-0.2°C (0.4°F) within 35.5~42°C (95.9~107.6°F), +/-0.3°C (0.5°F) for other range.
Fever alarm & Memory, °C / °F Switch function
Battery: one lithium cell battery (CR2032 *1pcs). Battery life is estimated at 3,000 readings. Enable normal use: 1 year
This thermometer converts the ear temperature to display its “oral equivalent.”(according to the result of the clinical evaluation)
E:LED Backlight (optional)
LED Backlight will be automatically turned on after measurement, and automatically turned off after 5 seconds.
There is no gender and age limitation for using infrared thermometer.
This is not an AP or APG product.
TH709L(E) Infrared Ear Thermometer Operating Instructions
0
2 years
2 years
Question and Answer IconNeed help?

Do you have a question about the Radiant Innovation TH709L and is the answer not in the manual?

Radiant Innovation TH709L Specifications

General IconGeneral
TypeInfrared Thermometer
Power Supply2 x AAA batteries
Dimensions155 x 40 x 40 mm
Weight68g (without batteries)
Auto Power OffYes
Display Resolution0.1°C
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 55°C
Measurement Time1 second
Battery TypeAAA

Summary

Operating Instructions

Temperature Taking

Steps for taking temperature, including probe cover insertion and ear preparation.

Power On

How to turn the device on and initial status indicators.

Taking Ear Temperature

Detailed steps for preparing the ear and inserting the probe for accurate readings.

Measuring

The process of initiating and completing a temperature measurement.

Power Off

The automatic shutdown feature and manual power-off.

Attentions

Crucial advice and precautions for accurate and safe thermometer usage.

Other Functions

Last Reading

Display of the most recent temperature measurement.

Memory Locations

Accessing and viewing stored temperature records.

Unit Conversion

Procedure to change the displayed temperature unit between Celsius and Fahrenheit.

Specifications

Normal Body Temperature

Temperature Variations by Age

Normal temperature ranges for different age groups.

Troubleshooting

Error Message Er

Probe cover not installed correctly.

Error Message Er1

System not functioning properly, requires battery reset.

Error Message Er2

Device showing rapid ambient temperature change.

Error Message Er3

Ambient temperature outside operating range.

Error Message H

Temperature taken is higher than +42.2°C (108°F).

Error Message Lo

Temperature taken is lower than +34°C (93.2°F).

Error Message 188.8

Device cannot be powered on to the ready stage.

Important Notes

Cleaning and Storage

Care instructions for cleaning the probe and storing the device.

Battery Replacement

Steps for replacing the battery and safety precautions.

Symbol Descriptions

Guidance and Manufacturer's Declaration - Electromagnetic Immunity

Guidance and Manufacturer's Declaration - Electromagnetic Emissions

Related product manuals