Installation, operating, commissioning and maintenance instructions.
CE
0694
RKA 34.20 - RAD - ING - MAN.INST - 1310.1 - DIGITECH CS - MIAH4
Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
Instruction Manual
for model
RKA 34 /20
Wall mounted storage combi boiler
premix condensing boiler

Questions and Answers

  • E
    Emily HallAug 17, 2025
    What to do if my Radiant Boiler has no water in the system?
    • D
      Diana WilliamsAug 17, 2025
      If there's no water in your Radiant Boiler system, it might be due to: insufficient water pressure (stops at 0.3 bar), in which case you should fill the system; a disconnected water pressure switch cable, so check the wiring; or a malfunctioning water pressure switch, meaning you should replace the part.
  • C
    Carol HendersonAug 20, 2025
    What causes inadequate circulation in my Radiant RKA 34 Boiler?
    • C
      Christopher MillerAug 20, 2025
      Inadequate circulation in your Radiant Boiler may be due to: an obstructed primary or secondary heat exchanger, which requires cleaning or part replacement; or a pump malfunction or dirty pump impeller, also requiring cleaning or part replacement.
  • K
    Kevin FrazierAug 22, 2025
    What to do if the safety thermostat tripped (95°C) in my Radiant RKA 34 Boiler?
    • L
      Lynn SandersAug 22, 2025
      If the safety thermostat has tripped in your Radiant Boiler, it could be due to: a thermostat malfunction or being out of calibration, which means you should replace the part; or a disconnected thermostat cable, so check the wiring.
  • K
    Krista AndersonAug 26, 2025
    What should I do if the 102° C thermo fuse tripped in my Radiant RKA 34?
    • R
      rhornAug 26, 2025
      If the 102° C thermo fuse has tripped in your Radiant Boiler, it may be because: the thermo fuse is broken, so replace the part; or the thermo fuse cable or power supply is disconnected, so check the wiring and the power supply connection.
  • J
    Janet BurgessAug 27, 2025
    Why is my Radiant RKA 34 Boiler's flame detection malfunctioning?
    • P
      Paula SwansonAug 27, 2025
      Flame detection malfunction in your Radiant Boiler could stem from: an ionization electrode malfunction, which requires replacement or cleaning; an ionization electrode cable malfunction, so replace the part; or a printed circuit board malfunction, also requiring part replacement.
  • J
    James WardAug 30, 2025
    What causes a heating sensor issue in my Radiant RKA 34?
    • C
      connorkingAug 30, 2025
      A heating sensor issue in your Radiant Boiler can be caused by: a sensor malfunction or being out of calibration (resistance value 10 kOhms at 25 °C), which means you should replace the part; or a sensor cable that is disconnected or wet, so check the power supply connection.
  • A
    Anthony AllenSep 2, 2025
    What causes a D.H.W sensor/cylinder issue in my Radiant RKA 34 Boiler?
    • D
      Darren LeeSep 2, 2025
      A D.H.W sensor/cylinder issue in your Radiant Boiler can occur due to: a sensor malfunction or being out of calibration (resistance value 10 kOhms at 25 °C), which means you should replace the part; or a sensor cable that is disconnected or wet, so check the power supply connection.
  • M
    melissa52Sep 4, 2025
    What causes a return sensor issue in my Radiant Boiler?
    • M
      Mary BrownSep 5, 2025
      A return sensor issue in your Radiant Boiler can arise from: a sensor malfunction or being out of calibration (resistance value 10 kOhms at 25 °C), so replace the part; or a sensor cable that is disconnected or wet, so check the power supply connection.
  • S
    stephen92Sep 7, 2025
    What causes FAN malfunction in Radiant RKA 34 Boiler?
    • J
      Joseph GardnerSep 8, 2025
      If the FAN malfunctions in your Radiant Boiler, it could be due to it being burnt or a power supply cable malfunction. In both cases, replace the part.
  • S
    Shelia BurgessSep 12, 2025
    What to do if the electric power supply of my Radiant RKA 34 Boiler is out of range?
    • S
      shelby17Sep 12, 2025
      If the electric power supply of your Radiant Boiler is out of the operation range (?160 /?285 volts), check the power supply network. The error disappears automatically when the power supply is back within the required range.

Summary

General Information

1.1 General Warnings

Provides safety warnings for installation, operation, and maintenance of the appliance.

Technical Characteristics

2.1 Technical Data

Presents detailed technical specifications including power, dimensions, and connections.

Installation (Authorised Personnel)

3.5 Water Connections

Details on connecting the central heating and domestic hot water circuits.

3.7 Gas Connection

Procedure and precautions for connecting the gas supply.

3.8 Electrical Connections

Instructions for safely connecting the boiler to the mains electricity supply.

Commissioning the Appliance (Authorised Personnel)

4.1 General Warnings

General safety precautions for commissioning and initial start-up procedures.

4.2 Filling the System

Step-by-step guide on how to fill the central heating and domestic hot water systems.

4.5 Starting Up the Boiler

Instructions for the initial start-up sequence and checks.

Regulating the Boiler

5.1 Parameters Table

Comprehensive table listing boiler parameters, their operation, values, and functions.

5.3 Setting the Parameters

Detailed instructions for setting various boiler parameters like model, gas type, and temperature.

Maintenance (Authorised Personnel)

6.1 General Warnings

General safety precautions and requirements for performing maintenance operations.

6.8 Troubleshooting

Lists error codes, their causes, remedies, and reset procedures.