Installation, operating, commissioning and maintenance instructions
CE
0694
RK 18_25 OV - RAD - ING - MAN.INST - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT
- CBD
Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH
Instruction Manual
for model
RK 18 OV
RK 25 OV
Premix condensing boiler

Other manuals for Radiant RK 18 OV

Questions and Answers

  • G
    Gregory BarajasAug 12, 2025
    What to do if my Radiant RK 18 OV shows a flame detection malfunction?
    • J
      Jody SalazarAug 13, 2025
      A flame detection malfunction in your Radiant Boiler can be attributed to a few reasons. The ionisation electrode may be malfunctioning, in which case you should clean it or replace the part. Another cause could be a malfunctioning ionisation electrode cable, which would require replacing the part. Lastly, the printed circuit board itself may be malfunctioning, also requiring a replacement.
  • C
    Christopher MoodyAug 20, 2025
    How to fix a tripped safety thermostat (95°C) in a Radiant RK 18 OV?
    • J
      Jennifer ThomasAug 20, 2025
      If the safety thermostat (95°C) has tripped in your Radiant Boiler, the thermostat itself might be malfunctioning or out of calibration, which means it needs to be replaced. Another possibility is a disconnected thermostat cable, so you should check the wiring.
  • B
    brandonblevinsAug 23, 2025
    What to do if my Radiant RK 18 OV has no water in the system?
    • T
      Tamara JohnsonAug 25, 2025
      If there's no water in your Radiant Boiler system, it might be due to insufficient water pressure (stopping at 0.3 bar), so you should fill the system. It could also be caused by a disconnected water pressure switch cable, so check the wiring. Another potential cause is a malfunctioning water pressure switch, which would require replacing the part.
  • A
    Andrew RossAug 28, 2025
    What causes a heating sensor issue in a Radiant RK 18 OV?
    • A
      Andrea PorterAug 28, 2025
      A heating sensor issue in your Radiant Boiler can occur if the sensor is malfunctioning or out of calibration (resistance value 10 kOhms at 25 °C), so you should replace the part. Another cause could be a sensor cable that is disconnected or wet, in that case you should check the electrical connection.
  • W
    William CherryAug 31, 2025
    What causes a Radiant Boiler fan to stop working?
    • K
      Katherine WilsonAug 31, 2025
      If the fan in your Radiant Boiler has stopped working, it may be due to a burnt fan, which requires replacing the part.
  • O
    Olivia GibsonSep 4, 2025
    What does a 'parameter programming request' mean for my Radiant Boiler?
    • B
      Bianca RobertsSep 4, 2025
      A 'parameter programming request' for your Radiant Boiler indicates a loss of microprocessor memory, so you should reprogram the parameters.
  • M
    Michele BerrySep 8, 2025
    What causes a flue safety thermofuse issue in a Radiant RK 18 OV Boiler?
    • R
      Raymond YoungSep 8, 2025
      A flue safety thermofuse issue in your Radiant Boiler is caused by a broken thermofuse, so you should replace the part.
  • M
    Mrs. Marilyn TaylorNov 15, 2025
    Why is there no flame in my Radiant Boiler?
    • A
      Amanda HowardNov 15, 2025
      The absence of a flame in your Radiant Boiler may stem from several causes. It could be due to a lack of gas supply, so check the mains supply. Alternatively, the ignition electrode might be broken or earthed, necessitating a replacement. A malfunctioning gas valve could also be the culprit, which would also require replacing the part. In some cases, the mechanical minimum adjustment or slow ignition adjustment on the gas valve may be set too low, requiring regulation. For LPG boilers, the gas valve inlet pressure might be too high, so check the maximum pressure setting. Incorrect wiring of the power supply (live and neutral wires inverted) can also prevent ignition; ensure the wires are connected correctly. Lastly, a malfunctioning ionisation electrode or a disconnected ionisation electro...

Summary

General Information

Installation Requirements

Reference Standards

Installation requirements and relevant standards for qualified installers in Great Britain and Ireland.

Boiler Installation

Mounting and Fixing

Step-by-step guide for mounting the boiler on the wall and making initial connections.

System Connections

Water and Condensate Connections

Detailed instructions for making central heating and condensate water connections.

Gas and Electrical Connections

Gas Connection

Procedures and safety checks for connecting the boiler to the gas supply.

Electrical Connections

General warnings and instructions for safe electrical connection of the boiler.

Flue System Installation

Flue Position Requirements

Regulations and recommendations for the correct installation of flue systems.

Commissioning the Appliance

Starting Up the Boiler

Step-by-step instructions for the initial start-up and testing of the boiler.

Regulating the Appliance

Setting Parameters

Instructions on how to navigate the menu and modify the boiler's operational parameters.

Gas Type Conversion

Annual Service and Maintenance

General Warnings

Important safety warnings and requirements before performing maintenance or service.

Maintenance Operations

Troubleshooting

Error Code Guide

Table of error codes, possible causes, and remedies for common boiler problems.

Commissioning Checklist

Radiant RK 18 OV Specifications

General IconGeneral
BrandRadiant
ModelRK 18 OV
CategoryBoiler
LanguageEnglish