www.SteamPoweredRadio.Com
Safety
Precautions
Safety
Precautions
Read and
follow
these safety precautions.
• Never
apply
voltages
to
the
meter
that
exceed
the
limits given in
the
specifications.
Never
apply
more
than 1000V
DC
or
750V
RMS
AC
between
the
input
jacks and
ground.
• Use extreme caution when
working
with voltages above
1
OOV.
Always
disconnect
power
from
the
circuit you are measuring
before
you
connect
test
leads
to
high-voltage
points.
• Never
connect
the
test
leads
to
a
voltage
source when you set
the
meter's
function
dial
to
•
1
>)/
i:lt-
,
0 /~ ~' LOGIC/Hz,
-:-:-JµA/
A,
or
-:-:-JmA/
A.
• Always discharge any capacitors
of
the
circuit
under
test
before
you attach
test
leads.
• Always turn
off
power
and
disconnect
the
test
leads
from
the
circuit you are
testing
before
you replace
the
meter's
battery
or
fuse. Never
operate
the
meter
unless its back cover and
battery
cover are in place and fully closed.
• Never try
to
probe
with
both
test
leads
at
the
same
time
or
hold
both
test
leads in
one
hand.
• The
test
leads
supplied
with your
meter
are rated
for
1000 volts. Use only
test
leads
of
the
same rating with
the
meter.
You
can
order
replacement leads
from
your local
RadioShack
store.
•
Do
not
use a fuse
brand
or
rating
other
than those specified here.
Doing
so
might
damage
your
meter
.
• Because many
AC/DC
sets have a
potentially
hot
chassis,
be
sure
the
top
of
your workbench and
the
floor
underneath
it
are
made
of
non-conductive
materials.
• Your
multimeter
is
designed
primarily
to
measure
household
AC
voltages.
Because
of
the
dangers inherent in measuring
three
-phase circuits, WE
STRONGLY
RECOMMEND
YOU
DO
NOT
USE
THIS METER
TO
MEASURE
3-PHASE, LINE-TO-LINE VOLTAGE. If you still
want
to,
put
on
protective
clothing-a
face shield and
fireproof
gloves and
upper
body
protection
is
required
before
measuring. If you
do
not
have this
protection,
DO
NOT
MEASURE THESE CIRCUITS.
•
To
reduce
the
risk
of
fire
or
shock hazard,
do
not
expose this
product
to
rain
or
moisture. For
indoor
use only.
•
When
you are
not
using
the
meter, always turn
it
off
.
• If this
equipment
is
used in a manner
not
specified in this user's
guide,
the
protection
provided
by
the
equipment
may
be
impaired
.
RadioShack.
4
This
meter
is
fully calibrated and tested.
Under
normal use,
no
further
adjustment
should
be
n~cessary. If
the
meter
requires repair,
do
not
try
to
adjust
it
yourself.
Take
it
to
your
local
RadioShack
store.
Special
Panel
Markings
&
CAUTION:
Risk
of
electric shock! Refer
to
the
complete
operating
instructions.
IA
CAUTION:
Be
extremely careful when making high-voltage
measurements;
DO
NOT
TOUCH TERMINALS
OR
PROBE ENDS.
[g]
The
meter
is
protected
by
double
insulation.
1
KV
.....
The maximum voltage
that
this
meter
can measure
is
10CX)V
DC
or
750V~
750V AC. The maximum current
that
this terminal can measure
is
400mA
400mA DC and AC.
MAX
+10A
MAX
The maximum current you can measure at this jack
is
10 amps DC/AC.
FUSED
This jack
is
fuse-protected.
CAT.
JI
This
equipment
is
rated
for
INSTALLATION CATEGORY
II
(3600VA
max).
soov
To
avoid electrical shock
or
instrument damage,
do
not
connect the
MAX
common
input
terminal
(
-COM
jack)
to
any source
that
exceeds 500
~
volts with respect
to
earth/ground
.
WARNING:
The sliding guard on
the
front
of
the
meter
protects against electrical
Shock Hazard
if guard not
shock.
Do
not
remove
the
guard.
installed.
Care
and
Maintenance
. Keep
the
meter
dry;
if it
gets wet,
wipe
it
dry
immediately
and make sure
that
the
meter
is
completely
dry
before
using
it
. Use and store
the
meter
only in normal
temperature
environments. Handle
the
meter
carefully;
do
not
drop
it.
To
keep
the
meter
looking
new, occasionally
wipe
it
with a cloth slightly
dampened
with water.
Do
not
use harsh chemicals, cleaning solvents,
or
strong
detergents
to
clean
the
meter. ·
RadioShack.
5