Upgrading an Installed Link Chapter 15
RADWIN 2000 User Manual Release  2.6.40 15-4
192.168.2.102,public,netman
3. Having created an update list, click Upgrade Package to chose the relevant files. 
The default files are located in the SWU subdirectory in the RADWIN Manager instal-
lation area. They are currently named SWU_1k.swu and SWU_2k.swu. You may 
have to find them elsewhere, depending on your system.
4. You make limited changes to the list by right-clicking any line:
Figure 15-5: Software Upgrade site options
5. To back up your existing system, check Backup device software check-box. Then 
click the   button for a standard file dialog. The default location is the My Docu-
ments directory on the managing computer or the last backup directory you used.
6. In addition to the previous step, you may opt to perform a delayed upgrade. Check 
the Delayed Upgrade box, and enter the date and time for the delayed upgrade.
7. The radio buttons on the right determines how your sites should be reset. Bear in 
mind that on the one hand, a reset involves a service interruption, but on the other 
hand, the software upgrade will not become effective until after the reset is carried 
out.
8. Click Start Upgrade to commence the process. For an immediate upgrade you will 
be able to observe the upgrade progress from the green progress bars:
Note
You can only include one type of ODU in a list. That is, you need separate 
list for WinLink 1000 and RADWIN 2000 products.
Note
The backup here is the same as that in page 8-50, and serves the same 
purpose. It provides a fallback if the upgrade proves problematic.