Hardware Installation Sequence Chapter 3
RADWIN 2000 User Manual Release 2.6.40 3-6
• IDU grounding cable 18AWG
• ODU-IDU cable (outdoor class, CAT 5e, 4 twisted pairs, 24AWG)
• An Ethernet LAN cable
Hardware Installation Sequence
The following steps are required to install the RADWIN 2000 system:
1. Mounting the ODUs, page page 3-7.
2. Mounting the external antennas (if used), page page 3-7.
3. Mounting the Lightning Protection devices (if used), page page 3-8.
4. Outdoor connections, page page 3-8.
5. Mounting the IDUs, page page 3-9.
6. Indoor connections, page page 3-12.
7. Aligning the ODUs/antennas, page page 3-13.
See Figure 3-8 below, which illustrates a typical installation of a RADWIN 2000 or a WinLink
1000 with external antenna(s).
Figure 3-8: Typical Installation (with external antenna) Left: RADWIN 2000 Right: WinLink
1000
The installation steps are detailed in the following sections.