Log-on Errors and Cautions Chapter 4
RADWIN 2000 User Manual Release 2.6.40 4-6
6. If your User Type is not Operator, then choose it now.
7. Enter the password.
8. If you are a user with Read-Write permission, click Options to enter the Community
options if required
9. For initial log on:
Leave the default Community passwords,
netman
for read-write, and
public
for
read-only.
If Community values were previously defined, enter them under Community in the
Read-Only or Read-Write boxes.
If you are a user with read-only permission, then you may only log on as Observer.
The RADWIN Manager main window is displayed (see Figure 4-10).
Log-on Errors and Cautions
Unsupported Device
Attempting to connect to an unsupported device on an otherwise valid IP address (for exam-
ple, a LAN printer) will result in the following error message:
Warning
If you log on using Local Connection, but your physical connection
is not local (i.e. anything other than a direct connection between the
managing computer and the IDU), then any configuration you carry
out may affect other links in the network. Do not do this!
Network log on (IP address to the ODU) is recommended.
If you log on via an over-the-air IP address, you will receive a warn-
ing. If you reset the site to which you are connected to factory set-
tings, you can lock yourself out of the link.
Note
The default IP address for the ODU is 10.0.0.120. The subnet mask is
255.0.0.0.
The actual IP address is defined during link configuration (see Site
Management: IP Address, VLAN and Protocol on page 8-10.
See also, Chapter 19).