6. Turn Off the Water and Drain the Plumbing
Turn off the water at the meter or the pressure tank.
To drain the plumbing system, open all faucets in the house and
flush the toilets. The water will drain out of the lowest faucet or
outlet.
Do not sweat pipes with water in them or while attached to the
system; steam will damage the plastic parts in the valve.
Do not point the soldering torch directly at the mineral tank or
control valve. These composite materials will last a lifetime, but
cannot withstand the intense heat from a torch.
Avoid short connections of pipe between the system and the
water heater. If you cannot avoid a short connection, move
the system to another location. As a last resort, install a heat
trap or check valve. If this causes “water hammer”, install a water
hammer suppressor.
7. Provide Untreated Water for Irrigation or
Outdoor Watering
If available, run an untreated water line to outside faucet or
provide a hose connection on untreated line prior to system.
9
Helpful Tip: This procedure will
allow air to enter the plumbing
system.
!
Important Note: Applicable for
copper plumbing installations.
Figure 1
!
Important Note: Short connections
of pipe may allow hot water
to back up into the system.
Recommend at least 10 linear feet
or 3 linear meters of pipe between
Conditioner and Water Heater.