OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends
referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2018 Unified Brands.
All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.
1055 Mendell Davis Drive, Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net
PART NUMBER PP MNL1803, REV. B (11/18)
This manual provides information for:
8000-290 SERIES PREP TABLES
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING R290 flammable refrigerant in use. Improper installation,
adjustment, alteration, service or maintenance can cause property
damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the
consignee to inspect the container upon receipt of same and to determine
the possibility of any damage, including concealed damage. Unified
Brands suggests that if you are suspicious of damage to make a notation
on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
NOTICE: Due to a continuous program of product improvement, Unified Brands
reserves the right to make changes in design and specifications without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain
recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER _________________________
SERIAL NUMBER _________________________
INSTALLATION DATE ______________________
The serial number is located behind the hinged vented
door of the compressor machine compartment. An
example is shown here.
EQUIPMENT DESCRIPTION
MODEL PAN
CAPACITY
1/3 SIZE
L D H DOORS STORAGE
CU. FT.
HP VOLT AMPS NEMA SHIP
WT.
WORK
SURFACE
REAR OF UNIT
(CLOSED COVER)
OVERALL
(COVER OPEN)
8148N-290 6 48” 33” 35” 44” 52.5” (1)27” 9.0 1/3 115/60/1 6 5-15P 405
8260N-290 8 60” 33” 35” 44” 52.5” (2)24” 14.67 1/3 115/60/1 6 5-15P 459
8268N-290 9 68” 33” 35” 44” 52.5” (2)27” 17.76 1/3 115/60/1 6 5-15P 484
8383N-290 11 83” 33” 35” 44” 52.5” (2)24”,(1)21” 23.55 (2) 1/4 115/60/1 5.8 5-15P 585
8395N-290 13 95” 33” 35” 44” 52.5” (3)27” 28.18 (2) 1/4 115/60/1 5.8 5-15P 630
84111N-290 15 111” 33” 35” 44” 52.5” (3)24”,(1)21” 32.81 (2) 1/4 115/60/1 5.8 5-15P 675
MODEL PAN
CAPACITY
1/6 SIZE
L D H DOORS STORAGE
CU. FT.
HP VOLT AMPS NEMA SHIP
WT.
WORK SURFACE
(NO CUTTING
BOARD)
REAR OF UNIT
(NO COVER)
OVERALL
8148W-290 21 48” 33” 35” 46.5” 53.5” (1)27” 9.0 1/3 115/60/1 6 5-15P 530
8268W-290 30 68” 33” 35” 46.5” 53.5” (2)27” 17.76 1/3 115/60/1 6 5-15P 595
8395W-290 42 95” 33” 35” 46.5” 53.5” (3)27” 28.18 (2) 1/4 115/60/1 5.8 5-15P 785

Other manuals for Randell 8395N-290

Questions and Answers

  • C
    cartershawnSep 2, 2025
    What to do if the Randell Food Prep Table triggers a high temperature alarm?
    • B
      baldwindavidSep 2, 2025
      If the high temperature alarm is triggered on your Randell Food Prep Table, begin by inspecting the door/drawer sealing. If the alarm persists, contact service.
  • J
    jessicalongAug 31, 2025
    Why does the Randell 8395N-290 have continuous compressor runtime?
    • J
      joshua42Aug 31, 2025
      If the compressor on your Randell Food Prep Table is running continuously, you should first inspect the door/drawer sealing. Then, inspect the condenser coil and clean it if necessary. If the problem persists, it is recommended to contact service.
  • D
    David Chan DVMAug 29, 2025
    What to do if my Randell 8395N-290 Food Prep Table does not run?
    • R
      Richard ThomasAug 29, 2025
      If your Randell Food Prep Table isn't running, start by ensuring the unit is properly plugged in and receiving power. Then, check if the control is in the OFF position and turn it ON. If these steps don't resolve the issue, it may indicate a faulty control, requiring a service call.
  • T
    Timothy ClarkAug 28, 2025
    Why is my Randell 8395N-290 Food Prep Table too warm?
    • J
      Justin WhiteAug 28, 2025
      If your Randell Food Prep Table is running too warm, several factors could be the cause. First, ensure the door or drawer is fully closed. Next, inspect the gasket for wear and proper positioning. Also, check that the control set point is correctly adjusted. Avoid placing warm items inside the cabinet; pre-chill them to 37ºF. Finally, if there's ice on the coil, initiate a manual defrost.
  • A
    Anna SchmidtAug 26, 2025
    How to adjust temperature if my Randell Refrigerator is too cold?
    • S
      sandersericaAug 26, 2025
      If your Randell Refrigerator is too cold, adjust the control set point to a warmer setting.
  • S
    stephaniemccallAug 25, 2025
    Why my Randell Refrigerator does not run?
    • N
      njosephAug 25, 2025
      If your Randell Refrigerator doesn't run, start by ensuring the unit is properly plugged in. If it is, check that the control is turned on. If the issue persists, it may be due to a faulty control, in which case you should call for service.
  • M
    Mary HenryAug 22, 2025
    What to do if my Randell Refrigerator is too warm?
    • A
      Ashley LawrenceAug 22, 2025
      If your Randell Refrigerator is too warm, first, make sure that the door or drawer is completely closed. Then, inspect the gasket for any tears or misplacement. Adjust the control set point if it's incorrect. Ensure that any product placed inside is pre-chilled to 37ºF. Finally, if there's ice on the coil, initiate a manual defrost.

Summary

INSTALLATION

OPERATION

Daily Operating Instructions

Procedures for daily use, startup, food safety, and shutdown.

DANFOSS CONTROLLER OPERATION

Manual Defrost and Temperature Control

How to perform manual defrost and adjust temperature set points.

REPLACEMENT PARTS

TROUBLESHOOTING

Common Unit Issues and Solutions

Guide to identifying and resolving common operational problems.

SERVICE AND REFRIGERANT HANDLING

R290 Refrigerant Procedures

Guidelines for handling R290 refrigerant.

WIRING DIAGRAMS

Single Compressor Configuration

Electrical schematic for single compressor units.

Double Compressor Configuration

Electrical schematic for double compressor units.