DAX60
60-WATT
POWER AMPLIFIER
DAX120
120-WATT
POWER AMPLIFIER
INSTALLATION AND SERVICE
KI-1480
RAULAND-BORG
CORPORATION
l
3450
West
Oakton
Street, Skokie, Illinois 60076-2951
l
(708)
679-0900
GENERAL DESCRIPTION
The Rauland DAK Series amplifiers are designed for use with Rauland's
institutional program and communication systems. They offer high-quality sound
and dependability. They can be driven to their rated power output by an input
signal as low as
0.3
volts.
Their transformer-isolated, 25-volt balanced out-
put matches the output of Rauland's communication panels; they also have a
70.7-volt
balanced output.
Their outputs can operate with a split center tap
with Rauland's
Telecenter®
5000 and Responder@ 3000 systems.
The amplifiers
are listed by Underwriters Laboratories,
The DAX amplifiers offer helpful power connections for related equipment:
three
120-VAC
three-pin grounded outlets,
and a floating auxiliary DC power
output (28 VDC, 1.2 A) that can be used for Rauland's Director Series control
panels, preamplifiers, graphic equalizer, and other equipment.
The amplifiers come with black-enamel face panels.
Optional
brushed-
chrome dress panels--
the RP2525
(DAX6O)
and RP2700
(DAX120)--are
available.
UNPACKING
The amplifier was thoroughly checked at the factory. Inspect the amplifi-
er,
the enclosed parts,
and the shipping container for signs of improper han-
dling during shipment.
In case of damage,immediately place a claim: with the
dealer or distributor from whom you purchased the unit or--if the unit was
shipped directly to you--with the carrier.
The following parts are included with the amplifier:
Description
Qty.
Rauland
Part No.
4
Rack-Mounting Screws for tapped holes
(l0-32
x
½"
hex-head,
WA202
SEMS, unslotted, machine).
4
Rack-Mounting Screws for untapped holes (10 x
½"
pan-head,
WA102
slotted,
thread-forming).
4
#l0
Tinnerman
"U"
type Speed Nuts, for untapped rack holes.
AB1889
INSTALLATION
The amplifier should be rack-mounted where there is adequate ventilation,
a moderate temperature, an AC power outlet,
and provisions for grounding.
The rack should have the standard
19-inch
width and a vertical space of at
least
5¼
inches
(DAX6O)
or 7 inches (DAX120).
It is recommended that
addition-
01987 RAULAND-BORG CORPORATION
PRINTED IN U.S.A.
7/87
Page 1 of 17