RAUMED NeuroSmart Instruction Manual
Manufacturer: RAUMEDIC AG, Hermann-Staudinger-Strasse 2, 95233 Helmbrechts, Germany
zwo-541EN Rev 3 / 2022-05-03
Page 1 of 61
Instruction manual
RAUMED
®
NeuroSmart
®
REF 095284-001 and
RAUMED
®
NeuroSmart
®
logO
095294-001
Edition with GUI Revision g3.22.
This document is for information only

Table of Contents

Questions and Answers

  • Y
    yatesbriannaAug 18, 2025
    What to do if my RAUMEDIC NeuroSmart logO shows 'Battery low'?
    • J
      Jessica HillAug 18, 2025
      If the RAUMEDIC Medical Equipment displays a 'Battery low' message, it means the device can operate for approximately 30 more minutes without a power adapter. Connect the adapter to continue operation.
  • C
    Christopher LopezAug 21, 2025
    Why can't I carry out zero calibration on my RAUMEDIC NeuroSmart logO Medical Equipment?
    • D
      Deborah WilliamsAug 21, 2025
      If the zero calibration fails on your RAUMEDIC Medical Equipment, it might be because the pressure changed by more than 2 mmHg. Ensure the pressure is stable and then repeat the zero balance procedure.
  • D
    Dorothy MartinezAug 23, 2025
    What to do if the measured values are constant on RAUMEDIC NeuroSmart logO?
    • C
      chaveztylerAug 23, 2025
      If the measured values on your RAUMEDIC Medical Equipment remain constant, it could indicate a defective or improperly connected catheter. Confirm this with OK. Check the pulsation of the pressure signals. If no pulsating pressure signals are displayed even though the catheter/transducer is connected to the patient, it is probably a sensor defect.
  • M
    Melissa RobinsonAug 26, 2025
    What happens when the data storage is full on RAUMEDIC NeuroSmart logO Medical Equipment?
    • J
      Joseph BlakeAug 26, 2025
      When the data storage of your RAUMEDIC Medical Equipment is almost full, save the data to a PC. Otherwise, the oldest data will be overwritten.
  • J
    Jodi FordAug 27, 2025
    Why is the connection with NEUROVENT P-tel interrupted in RAUMEDIC NeuroSmart logO?
    • S
      Stephanie HughesAug 27, 2025
      If the connection with the NEUROVENT P-tel is interrupted on your RAUMEDIC Medical Equipment, the NEUROVENT P-tel may be outside the reader's transmission range. Check the reader’s location and correct it if necessary.
  • V
    Victoria WilliamsAug 30, 2025
    How to fix 'No connection to NEUROVENT P-tel possible' on RAUMEDIC?
    • J
      Jesse PriceAug 30, 2025
      If no connection to the NEUROVENT P-tel is possible with your RAUMEDIC Medical Equipment, check the position of the reader antenna.
  • W
    wphamSep 1, 2025
    Why is the amplitude of the measurement signal too low on RAUMEDIC NeuroSmart logO?
    • T
      Thomas MillerSep 1, 2025
      If the amplitude of the measurement signal for the oxygen partial pressure is too low on your RAUMEDIC Medical Equipment: * Check the catheter and the oxygen socket. * Check the plug connection and fibre optic cable. Clean the ST socket on the NeuroSmart and ST plug on the catheter.
  • N
    Nicholas StephensSep 3, 2025
    How to correct a system time failure on RAUMEDIC Medical Equipment?
    • J
      John GonzalezSep 4, 2025
      If there is a system time failure on your RAUMEDIC Medical Equipment, check the date and time and correct them if necessary.
  • K
    kyle12Sep 6, 2025
    What to do if the O2 catheter is faulty on RAUMEDIC Medical Equipment?
    • R
      raymond17Sep 6, 2025
      If the connected O2 catheter is faulty on your RAUMEDIC Medical Equipment, use another catheter.
  • C
    christophermooreSep 8, 2025
    What to do if temperature channel is defective on RAUMEDIC NeuroSmart logO Medical Equipment?
    • S
      Sarah ParrishSep 8, 2025
      If the temperature channel is defective or the temperature T2 is outside the measuring range on your RAUMEDIC Medical Equipment, check the cables and catheters or switch off T2.

Summary

General Information

Contra-indications

Lists medical conditions or situations where the device should not be used.

Safety Instructions

General Safety Guidelines and Precautions

Essential rules for safe operation, handling, and maintenance of the device.

Operation

Operating Functions and Concepts

Overview of the device's main and important operating functions and its overall operating concept.

Start-up Procedures

Step-by-step guide for initiating the NeuroSmart device and its initial setup.

Starting a Measurement

Measurement Preparation and Execution

Guides on preparing for pressure measurement and executing different measurement types.

Adjusting Settings and Installation

General Settings Configuration

How to adjust system language, scaling, alarm limits, and other general device settings.

Alarm System

Physiological Alarm Limits Configuration

Setting and adjusting physiological alarm limits for accurate patient monitoring.

Analogue Forwarding of Measured Parameters

Error Messages and Troubleshooting

Physiological Error Messages

List of physiological errors and recommended troubleshooting steps.

Technical and Internal Error Messages

List of technical and internal system errors with troubleshooting guidance.

Electromagnetic Compatibility (EMC)

Inspections, Safety, and Measurement Checks

Mandatory Safety and Measurement Checks

Requirements and recommendations for periodic safety checks and measurement verification.

Technical Parameters and Specifications

RAUMEDIC NeuroSmart logO Specifications

General IconGeneral
BrandRAUMEDIC
ModelNeuroSmart logO
CategoryMedical Equipment