Lists key technical specifications for the deflection unit.
Lists key technical specifications like resolution, repeatability, and IP-code.
Specifies the voltage, current, and ripple/noise requirements for the power supply.
Details the analogue and digital control signal specifications.
Highlights electrical, laser radiation, and falling unit hazards during installation.
Details critical safety measures and warnings for start-up and ongoing operation, including handling of mirrors and laser beams.
| Type | Galvanometer Scanner |
|---|---|
| Aperture | 10 mm |
| Scan Angle | up to ±20° optical |
| Wavelength Range | 1064 nm |
| Input Voltage | ±15 V DC |
| Interface | analog |