Note:
Thesuitablefuseratingforthethermalbreaker
isdependentonthenumberofdevicesyouare
connecting.Ifindoubtconsultanauthorized
Raymarinedealer.
Yourproduct’spowercablemayhavetted
in-linefuse,ifnotthenyoucanaddanin-line
fusetothepositivewireofyourproductspower
connection.
5.5Extensioncableconnection
Anoptionalextensioncablecanbeusedtoextend
thedistancefromthetransducertotheunitbyup
to4m(13.1ft).
12 V dc
D13241-1
2
1
3
1.Existingcable.
2.Extensioncable(connectedtothevessel’s
powersupplyandtotheexistingcable.
3.Isolatedpowersupplywiresonexisting
transducercable.
Note:
Only1extensioncableshouldbeusedper
installation.
Thelengthofthepowersupplywiresonthe
extensioncableis2m(6.6ft).
Maximumtransducercablelength
Themaximumcablelengthfromthetransducerto
theunitisshownbelow.
CPT-DV8m(26.2ft.)4m(13.1ft.)
suppliedcable+4m(13.1ft.)
extensioncable
CPT-DVS10m(32.8ft.)6m(19.7
ft.)suppliedcable+4m(13.1
ft.)extensioncable
Note:Extendingthetransducercablefurtherthan
themaximumstateddistancewillcausepoor
performance.