EasyManua.ls Logo

Raymarine SmartPilot S1 Wheel Pilot - Page 48

Raymarine SmartPilot S1 Wheel Pilot
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 S1 Wheel and Tiller Pilots Commissioning Guide
Accessing the Calibration modes
Y ou can only access Calibration mode from Standby mode:
1. With the SmartPilo t in Standby mod e, press and h old the
standby
k ey for 2
second s. T he display will change to show
DISPLA Y CAL
.
2. Press the
disp
k ey to scroll through the 4 cali bration groupings:
Displa y Calibratio n (
DISPLAY CAL
)
User Calibration (
USER CA L
)
Seatrial Calib ration (
SEATRIAL CA L
)
Dealer Calib ration (
DEALER CAL
)
Note:
You can go backwards through the groups by pressing and holding the
disp
key for
one s econd.
3. When you reach the Calibration group you w ant to access, press
auto
to
enter t hat gro up:
T o prevent accidental access , we have made entry to Dealer Calibration more
+
Accessing
Calibration Modes
2 seconds
2 seconds
(saves changes)
Calibration
Modes
to enter seatrial
calibration mode
D9331-1
to enter dealer
calibration mode
to enter display
calibration mode
to enter user
calibration mode
CAL ?
81282_1.book Page 36 Monday, October 2, 2006 1:58 PM