EasyManuals Logo

Raypak 6350 Series User Manual

Raypak 6350 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16
Fault Code Meaning of Code
OFF The desired programmed temperature point is lower than 60°F (15°C).
L
P & LP3
Shortage of refrigerant gas in the unit or faulty low pressure control. The unit will show
(
LP3) after 3 LP faults and shuts down the unit and pool pump for protection. If this
occurs, you should call for service.
HP & HP6
Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The
unit will show (HP6) after 6 HP faults. This will stop the unit for protection.
FLo & FL3
Possible causes:
• The filter is in backwash position.
• The filter pump is stopped.
• The filter is dirty.
Shortage of water to pool pump.
Water pressure switch must be adjusted or it is broken.
• The unit is in the protection mode and will show (FL3), press any key to restart the unit.
FL3 code will stop the unit and pool pump.
FS
Unit is in the defrosting cycle.
(The fan works but the compressor is stopped.)
- - Keypad is pressing down on both buttons. Replace keypad.
Table C: Control Board Fault Codes Digital Models

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raypak 6350 Series and is the answer not in the manual?

Raypak 6350 Series Specifications

General IconGeneral
BrandRaypak
Model6350 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals