Raytech USA, Inc. All rights reserved Ver. 1.13 5
SPECIFICATIONS 4 – 0
MODEL: TR-1 & TR-1P
SIZE: L: 10.62” (270 mm) W: 9.68" (245 mm) H: 4.87” (125 mm)
WEIGHT: 7 lbs. (3.2 kg)
INPUT POWER: 100 to 240 vac 50/60 Hz : for Internal Battery charger
TEST VOLTAGE: User Selectable: 40, 10, 5, 1 and Automatic mode
PANEL DISPLAY: LCD Graphic with back lighting
FRONT PANEL: Sealed, Anodized Aluminum
INTERFACE: RS232 with optional interface
MEMORY STORAGE: Internally stores 50 measurements
MEASUREMENT PARAMETERS
TURNS RATIO RANGE: 0.8 ... 4000.0
RESOLUTION: 5 Digits
ACCURACY:
Range 0.8 ..... 4000 0.08 % with 40 Volt (PT Mode)
Range 0.8 ..... 100 0.08 % with 1…5V (Auto & CT mode)
TEMPERATURE: Operating: - 10 C to 60 C Storage: - 20 C to 70 C
CABLE SET / ACCESSORIES
5 meter Single Phase cable set, 5 meter Safety Ground lead, 3 meter Power cord, Instruction Manual, and
instrument carry case with shoulder strap. * TR-1P includes paper refills for the panel mount printer.
TR-1 FEATURES:
• Automatic measurements of Turns Ratio and Current
• Automatic detection of correct connection to transformer
• Designed not to run a test until correctly connected to transformer
• Internal Lithium-Ion Battery
• Internal storage for test results
• Single push button operation
• Ratio testing from 0.8 to 4000.0 turns
• Multiple test voltage ranges
• Load on test object < 0.05 VA
• Heavy-duty protection circuitry
• RS232 (serial) Interface
• 5 Year standard warranty
TR-1P FEATURES (Same as above plus):
• Panel mount printer
TR-1 & TR-1P OPTIONAL ITEMS:
Part No: 1002A-05002 – 10 Meter extension lead
Part No: 2040X-18002 – (5) Paper refills for panel mount printer (TR-1P only)
Part No: 1011N-23001 – RS-232 adapter
Part No: 1011N-24002 – 12VDC Automotive Adaptor
Part No: 1011N-23002 – Serial Interface cable and Software
* Specifications are subject to improvement at anytime.