Do you have a question about the RBH Sound UNC500 and is the answer not in the manual?
Specific requirements for ULC-S319-05 III compliance regarding wiring and installation.
Guidelines for establishing a proper earth ground connection for optimal protection.
Explains how the UNC500 communicates via Ethernet and RS485.
Details the three supported network types: Host, Device, and Controller.
Describes the capabilities of the eight outputs, including relays and electronic drivers.
Information on the thermal fuse protected auxiliary power output.
Details the eight supervised inputs and their programmable configurations.
Covers Wiegand interfaces, reader tamper inputs, and LED/beeper outputs.
Explains fuse monitoring, diagnostic LEDs, and tamper detection.
Visual guide to the connectors, indicators, and controls on the UNC500.
Details direct power connection, POE, and internal battery charger/monitor.
Explains different applications for the RS485 ports (HOST, D-NET, D-NET2, UNC-NET).
Covers DIP switch functions for address, baud rate, and other settings.
How to set the controller's address using DIP switches 1-4.
Defines master controller and slave controller roles in a network.
Functionality of DIP switch 5 for securing Ethernet access.
Setting the controller's serial port baud rate using DIP switches 6 and 7.
Using DIP switch 8 to disable the internal RC-2 for NC100 replacement.
How to connect to a PC and details of RS485 wiring and cable specs.
Twisted pair, shielded, 18 to 22 AWG cable for RS485.
The maximum allowable cable length for RS485 connections.
Connecting the UNC500 via Ethernet and configuring IP addresses.
Illustration of PC to UNC500 connection via LAN.
Using Telnet to program the UNC500, including IP and application settings.
Using IP Search to find and configure connected devices.
Using the IP locator program to edit device parameters.
Explains CNET and UNC-NET for controller communication.
Details the CNET for linking controllers, with diagrams.
Details the UNC-NET for linking controllers, with diagrams.
How NIRC2000/NURC2000 provide RC2 functionality in Axiom.
Discusses differences from RC2, including lack of power supply and fewer I/O.
How reader tamper inputs monitor AC failure and low battery.
Notes on cabinet tamper reporting and fuse monitoring status.
Explains the limitation of single channel for dual RS485 communication.
Details power input, voltage, and current consumption.
Information on the 32-bit processor and available memory options.
Maximum number of controllers and readers supported.
Specifications for C-NET and D-NET network types.
Supported protocols for PC and remote communications.
Includes dimensions, operating temperature, and humidity.
Specifies CAT5 cable for PC to controller Ethernet connection.
Details cable type, shielding, gauge, and length for RS485.
Cable requirements for UNC-NET ring sections and total length.
Cable requirements for D-NET ring sections and total length.
Cable specifications for connecting RC-2 readers.
Cable type and maximum length for input port circuits.
| Brand | RBH Sound |
|---|---|
| Model | UNC500 |
| Category | Controller |
| Language | English |