EPSILON ES2,ES4
55
1-9600bps
2-19200bps
3-38400bps
4 -57600bps
At$baud=1,2
2. Set the data reading from the FLS
At$fuel=<Option>, <Time>,< Frequency >, <Temperature in degrees of centigrade>,<Level>
<Option> 0-prohibited, 1- allowed
<Time> Minimal time in seconds in the range of 1...65535 sec.
<Frequency>, < Temperature in degrees of centigrade>,<Level> -fuel data, fuel volume range
of 0...1024
Example: At$fuel=1,60 –to set data reading from FLS every 60 seconds.
Fuel data comes in a standard protocol Intellitrac A1 according to the settings, as additional 6
bytes
<Asynchronous send>+<Fuel data>
Using the "IntelliTrac A1" with one FLS it is necessary during sensor’s configuration to set the
text format of the data.
Using the "IntelliTrac A1" with the concentrators of sensors "DALCON" (see Appendix 4) you
have to install a text format of the data during the configuration of DALCON (see Picture A4.6).
You must also coordinate the exchange speed on the serial port in one of the ways:
-either set in the sensor exchange speed equal to the exchange speed in "IntelliTrac A1" (see
Picture A4.3)
-or set it in "IntelliTrac A1" by command AT$BAUD with a parameter equal to exchange speed
in the sensor or in DALCON.
To enable transfer of data about the level of fuel in "IntelliTrac A1", use the command
AT$FUEL.