Averaging time data - 15 ... 60 c or off (depending on the particular problem).
Team: LLSAVER TIME = 15
Test run: LLSAVER TIME?
Notice. Disabling the averaging or the installation is too small values of the averaging time is the
accumulation of redundant data, which can lead to increased consumption of GPRS traffic on
their gear!
Time delay start of measurement and data - 3 ... 5.
Team: LLSSTART DELAY = 3
Test run: LLSSTART DELAY?
Notice. EPSILON FLS starts to give valid data at 1 ... 2 seconds after power-up.
Termination of the waiting time of packets from the fuel gauge - 30 seconds (the default).
Team: LLSFINISH DELAY = 30
Test run: LLSFINISH DELAY?
The calibration procedure FLS "EPSILON"
1) Run "eS Install" (see details in Appendix 1)
2) On the tab "General Options sensor", set the following parameters of the measuring head:
• "The network address of the device": 1
• "Retry interval": 1
• "Bit" 10-bit
"On. Periodically issue": the regime is included for LLS TYPE = 1 and has no value for the
mode LLS TYPE = 4
• "On. Text format": disabled
"The rate of exchange on the UART": 19200 bits / s (may be modified depending on the
problem under the condition of equality of exchange rates in the FLS and device traffic
monitoring)