Built-in Installation
For non-combustible cabinet enclosure installation only. Follow the cut-out dimensions
as shown. ALL outdoor kitchen cabinets MUST include ventilation. There must be
12 square inches of opening for each (running) 4 feet of counter top. See Item # RVNT1
for approved vents. In the event of an installation in a combustible (wooden) cabinet,
you must use an insulated jacket available from RCS.
Model/Part Number
RWGM - RJC26A/RJC32A/RJC32AL/RON30A
RWGL - RJC40A/RJC40AL/RON38A/RON42A