Data setting and store the specified data group.
Page up or page down to M-PRE, and then press shortly the coding
potentiometer to enter into the status of choosing the data groups. Turn coding
potentiometer to choose the data group you need to view. Then the data group
you need will be displayed. Then press the coding potentiometer to enter
into status of changing output state. Turn coding potentiometer to choose ON
or OFF. When choose ON, the data group is extracted and the output status
remain the same. When choose OFF, the data group is extracted and the
output is closed. If you want to exit choosing the data group, press shortly.
Then press shortly or to page up or page down to other place to adjust
the data you need. After data setting done, keep pressing more than 2s,
all the data you set are automatically stored into the specified data group. In
the same time, you can see the group number on the right of screen. Now you
can press shortly back to the main interface.
Function description
Open or close the output:
You can press to open or close the output on any interface.
Lock the button to avoid wrong operation:
On the any interface, you can keep pressing coding potentiometer more
than 2s, all buttons are locked. You can see the key lock icon on the right of
screen. If you want to unlock all buttons, keep pressing coding potentiometer
more than 2s, all buttons are unlocked. The key unlock icon will be display on
the right of screen.
M0-M9 ten data groups:
M0 group is the boot default data group. When you extract the data group
you need, this data group will cover M0 data group and be automatically stored
on M0 data group.
Extract Shortcut storage data group M1 or M2:
On the main interface, keep pressing or more than 2s, the
corresponding data group will be extracted. In the same time the
corresponding data group number will displayed on the right of the screen.
Extract the specified data group:
On the main interface, keep pressing more than 2s, the sequence
number of data group will be displayed on the right of the screen, you can turn
coding potentiometer to choose data group you need. Then press shortly,
you can extract the specified data group you need.