Install DA50A- B
Drawing No. LP1155
Effective 06/2020
DA50A FlexEdge™ 1-Sled Gateway
Installation Guide
1
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
T4
C
US
U
L
R
IND.CONT. EQ.
E317425
z Modular architecture allows for upgrading of software and
hardware capabilities
z Advanced networking capabilities including routing, NAT, and
firewall features
z Enhanced automation, IIoT and Crimson Control capabilities
are model specific
z Fully isolated design provides reliable operation
z Independent serial ports provide virtually unlimited
integration methods
z 10 Base-T/100 Base-TX Ethernet connection provides
networking capability
z Configured using web GUI or Crimson
®
software (version 3.2
or later)
GENERAL DESCRIPTION
The DA50A provides networking and automation capabilities in
a modular architecture to ensure easy deployment in any
industrial application. This modular design makes ensuring
compatibility with rapidly evolving communications standards as
easy as replacing a field-installable sled. Easily upgrade the
gateway to a more advanced feature set to meet changing
application requirements. With an intuitive LED status ring,
diagnosing issues is simple and straightforward. The DA50A
delivers a compact adaptable solution that securely connects
industrial applications.
GATEWAY PACKAGE CHECKLIST
This product package should contain the items listed below.
This list does not include any sleds that may have been ordered.
If any items are missing or damaged, contact Red Lion immediately.
- DIN Rail Mount DA50A Gateway
- Pre-installed Sled Holder
- Installation Guide
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
CAUTION: Risk of Danger
Read complete instructions prior to installation and
operation of the unit.
ATTENTION : Risque de danger
Lire les instructions complètes avant l’installation et
l’utilisation de l’appareil.
WARNING - EXPLOSION HAZARD - SUBSTITUTION
OF COMPONENTS MAY IMPAIR SUITABILITY FOR
CLASS I, DIVISION 2
AVERTISSEMENT - DANGER D’EXPLOSION - LE
REMPLACEMENT DE COMPOSANTS PEUT NUIRE
L’APTITUDE À LA CLASSE I, DIVISION 2
This equipment is suitable for use in Class I, Division 2,
Groups A, B, C, D, or non-hazardous locations only.
Cet équipement est adapté à une utilisation dans des
endroits de classe I, Division 2, Groupes A, B, C, D, ou
dans des endroits non dangereux seulement.
WARNING - EXPLOSION HAZARD. NOT HOT
SWAPPABLE. DO NOT REMOVE OR REPLACE WHILE
CIRCUIT IS LIVE UNLESS THE AREA IS FREE OF
IGNITIBLE CONCENTRATIONS.
AVERTISSEMENT - RISQUE D’EXPLOSION. PAS
ÉCHANGEABLE À CHAUD. NE PAS RETIRER OU
REMPLACER TANT QUE LE CIRCUIT EST SOUS
TENSION SAUF SI LA ZONE EST EXEMPTE DE TOUTE
CONCENTRATION INFLAMMABLE.
II 3 G Ex ec IIC T4 Gc
DEMKO 20 ATEX 2268X
IECEx UL 20.0007X