1
! 0.3" (7.6 mm) HIGH, 6 DIGIT DISPLAY
! NON-VOLATILE MEMORY (E
2
PROM)
! DISPLAY SCROLLING (SELECTABLE)
! BI-DIRECTIONAL COUNTING
! PRESCALE CAPABILITY WITH DISABLE SWITCH (Dual Preset)
! FORM C RELAY OUTPUT(S)
! SOLID-STATE CURRENT SINKING OUTPUT(S)
! PROGRAMMABLE TIMED OUTPUT(S)
! REMOTE RESET CAPABILITY
! ABILITY TO LOCK OUT FRONT PANEL FUNCTIONS
! ACCEPTS INPUT COUNT RATES UP TO 15 KHz (Single preset)
! AVAILABLE IN AC OR DC VERSIONS
! FRONT PANEL PROGRAMMABLE DECIMAL POINT
! SEALED FRONT PANEL CONSTRUCTION (NEMA 4X/IP65)
DESCRIPTION
The Lynx Series of presettable counters is an economical and reliable
solution to single or dual preset level requirements. The Model LNXC1 is the
single preset version and the Model LNXC2 is the dual preset version. Both
units have a solid-state output and a Form C relay output for each preset. These
units feature selectable input configurations, a full compliment of control
inputs, programmable timed outputs, prescale capability with disable switch
(dual preset only), non-volatile memory, and many other features which will
satisfy most any single or dual preset application.
The Lynx Counters have two main counting actions, Reset to Zero (RTZ) and
Reset to Preset (RTP). There are eight modes of operation for the single preset
unit and sixteen for the dual preset unit.
All parameters are programmed through the front panel buttons. The Lynx
counters have an internal non-volatile memory device which eliminates the
need for battery back-up. When power is removed, this device will maintain all
data set-ups necessary for system operation. A Program Disable terminal is
provided, which can be used to prevent accidental changes or tampering by
unauthorized personnel to the preset(s), prescale or timed output values. The
front panel reset button can also be enabled or disabled by a rear panel DIP
switch. These counters also have an on-line self-test, which can be run at any
time without missing counts or missing a preset value.
Power, input, and output connections are made via removable terminal blocks
at the rear of the unit. The Lynx Series of counters have a sealed high impact
plastic bezel and meet NEMA 4X/IP65 specifications for wash-down and/or
dust, when properly installed.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
1. DISPLAY: 6-digit, 0.3" (7.6 mm) high LCD display.
2. POWER REQUIREMENTS:
AC Power Versions: 115 VAC (±10%), 50/60 Hz, 6 VA
230 VAC (±10%), 50/60 Hz, 6 VA
DC Power Versions: 11 to 14 VDC @ 180 mA.
21.5 to 30 VDC @ 180 mA.
3. SENSOR POWER: +12 VDC (±25%) @ 100 mA.
4. COUNT INPUT: DIP switch selectable to accept count pulses from a variety
of sources, including switch contacts, outputs from CMOS or TTL circuits,
and all standard RLC sensors.
Current Sourcing: Unit provides 3.9 K pull-down load for sensors with
current sourcing outputs. (Max. input voltage, 28 VDC @ 7 mA.)
Current Sinking: Unit provides 7.8 K pull-up to +12 VDC for sensors
with current sinking outputs. (Max. sensor current, 1.6 mA.)
Debounce: Damping capacitor provided for switch contact debounce. Limits
count speed to 100 cps max. with 50% duty cycle.
Lo Bias: Input Trigger levels V
IL
= 1.5 V, V
IH
= 3.75 V
Hi Bias: Input Trigger levels V
IL
= 5.5 V, V
IH
= 7.5 V
Note: Bias levels ±10% @ 12 VDC sensor voltage. These levels vary
proportionally with the sensor supply voltage.
5. PRESCALE VALUE RANGE: 0.00001 to 9.99999 (dual preset unit only).
MODEL LNXC1 SINGLE PRESET COUNTER
MODEL LNXC2 DUAL PRESET COUNTER
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.7" (68.6)H x 4.0" (101.6)W.
PANEL CUT-OUT
CAUTION: Read complete instructions prior
to installation and operation of the unit.
CAUTION: Risk of electric shock.
Bulletin No. LNXC1/2-D
Drawing No. LP0289
Released 5/03
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com