EasyManua.ls Logo

RED SHIELD WS500 User Manual

RED SHIELD WS500
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
USER GUIDE
WIRE-FREE HOME PROTECTION SYSTEM WS500
Section 1 – Getting started
1.1 General system overview
1.2 Introduction to the system
1.3 Items included with the system
1.4 Introduction to the Smart Panel
1.5 Introduction to the Smart Panel backlight
Section 2 – Installing the Wire-free Home Protection System
2.1 Installing the Smart Panel
2.2 Powering up the Smart Panel
2.3 Understanding the battery and AC adaptor icon
Section 3 – Using the Wire-free Home Protection System
3.1 Programming your 4-digit PIN
3.2 Transmitting an emergency (Panic) alarm
3.2.1 Using the Panic alarm
3.2.2 Using the Panic alarm without activating the siren
3.3 Operating different modes
3.3.1 STANDBY mode
3.3.2 ARM mode
A. Adjusting Exit Delay
B. Adjusting Entry Delay
C. Adjusting the Alarm Duration
D. Muting the Audible Countdown
E. Arming the system
F. Disarming the system
G. Zone settings
H. Triggers in ARM mode
3.3.3 ALERT mode
A. Entering the ALERT mode
B. Exiting the ALERT mode
C. Zone settings
3.3.4 HOME mode
A. Entering the HOME mode
B. Exiting the HOME mode
C. Zone settings
Section 4 – Installing the Sensors
4.1 Introduction to the Sensors
4.2 Installing the Sensors
4.2.1 Installing the Door/Window Sensor
A. Powering up the the Door/Window Sensor
B. Installing the Door/Window Sensor
C. Mounting with the double-sided adhesive pad
4.2.2 Installing the Motion Sensor
A. Powering up the Motion Sensor
B. Installing the Motion Sensor
C. Sensor sensitivity
D. Walk test
E. Mounting using screws
4.2.3 Introduction of Key Fob Remote Control
A. Introduction
CONTENTS
B. Operation
i. Powering up the Key Fob Remote Control
ii. Enrolling the Remote Control onto the Smart Panel
iii. Operating the Key Fob Remote Control
iv. Deleting a Remote Control from the Smart Panel
v. Querying the ID Number of a Remote Control
4.3 House Security Code settings
4.4 Zone Code settings
Section 5 - Troubleshooting
5.1 FAQ
5.2 Troubleshooting
Section 6 – General Information
6.1 Product information
6.2 Specifications
6.2.1 Smart Panel
6.2.2 Key Fob Remote Control
6.2.3 Door/Window Sensor
6.2.4 Motion Sensor
6.3 Maintenance
6.4 Batteries
1
3
5
13
WS500_Rev.A_20140918

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the RED SHIELD WS500 and is the answer not in the manual?

RED SHIELD WS500 Specifications

Smart Panel

Power IconPower
power sourceAC adaptor
back up power9V alkaline battery x1pc
Operating Specifications IconOperating Specifications
operating frequencies433.92MHz +/-0.5MHz
siren output120dB (Duration-adjustable)
sensor numbersUnlimited

Key Fob Remote Control

Power IconPower
power source12V alkaline battery x 1pc
Operating Specifications IconOperating Specifications
RF working transmission frequency433.92MHz +/-0.5MHz
wireless range to Smart Panel<65 meters (215ft, open area)
house code4 Jumpers

Door/Window Sensor

Power IconPower
power sourceAAA alkaline battery 1.5V x 2pcs
Operating Specifications IconOperating Specifications
RF working transmission frequency433.92MHz +/-0.5MHz
wireless range to Smart Panel<150 meters (500ft, open area)
house code4 Jumpers

Motion Sensor

Power IconPower
power source9V alkaline battery x1pc
Operating Specifications IconOperating Specifications
RF working transmission frequency433.92MHz +/-0.5MHz
PIR detection angle<110 Degree (@9VDC)
PIR detection range“H”:< 15M(50ft); “M”:< 6M(20ft); “L”:< 4M(13ft)
wireless range to Smart Panel<150 meters (500ft, open area)

Related product manuals