64
O
15-CLEANING AND MAINTENANCE
CLEANING THE TROLLEY
Red recommends checking the level of the ash inside the trolley every 15 days with the boiler switched o and in any case empty the
container every two months(*).
Carry out this check as follows:
• turn o the boiler
• disconnect the trolley from the boiler with the two side levers
• close cap “O” near the feed screw insertion hole (to avoid loosing ash during transport)
• open the trolley cover with the two levers
• check the level of the pellets
If the level of ash is more than 50%, empty the container.
Two more steps are required before replacing the trolley:
• check the ash pan and empty it, if necessary (see explanation on the following pages)
• check the cleanliness of the brazier (see explanation on the previous page)
In any case, check the level of the ash deposited in the trolley every 15 days.
*The frequency with which the trolley, lower ash pan and
brazier must be cleaned depends on the type of pellet used. See
the instructions on the previous page.