CHECK THE GAS TYPE THE DEVICE IS ADJUSTED FOR
Check whether the device is set for the gas type you use. The gas type is indicated on the label of each
device.
Process of rebuilding the device for another gas type
The device is set and checked for lique ed gas (see the label). Rebuilding for another gas type must be done
by quali ed person. Nozzles are included in the packet with instructions for use.
Exchange of the main burner´s nozzle: picture D
Screw up and remove the bottom cover(1), screw up the nozzle and screw (2) in the new one for required gas
type - see technical chart. You need not to regulate air feeder.
Important:
After having rebuilt the gas type, change the data on the label.
How to check the operation of the device:
• check the gas leaks
• check the ignition and ame of the main burner
• check the ignition and ame of the main burner for min. performance (sporo)
• check whether the ame of the burner licks the thermoelement and whether it is blue
• we recommend to the user when using the device to proceed according to the instructions for use
Regulation of the fl ame by the lower performance (sporo):
Adjust the low performance (sporo) and then regulate the ame with screw which is situated in the body of
the tap next to the tap shaft.
Process of regulation:
• remove the regulation tap knob (pull to yourself)
• there is slot for regulation next to the tap shaft
• regulate the ame with the small at screwer
Maintenance:
We recommend you to have the device checked once a year by proffesional service. Only quali ed or
competent persons can do interventions in the product.
It may be necessary to exchange some parts during the useful life of the device:
piezzo electrode, sensor of the thermofuse
Exchange of the piezzo electrode or thermofuse sensor: picture D
Screw up and remove the bottom cover (17), screw up the holder of the electrode and the sensor (26),
disconnect and remove the electrode (27) or sensor (23). The tting up of new part must be done in the
contrary.
PIPE FOR GAS CONNECTION
It must rst determine if the appliance is made for the same type of gas that will be used and thus conforms
to the indications on the label the type of gas to be used.
The conversion of gas pan to another type of gas you need to check if it corresponds to the type of gas
bearing, which is recommended in this guide.
Connecting the appliance to the gas distribution must be towable to a steel or copper tube complying with
applicable national requirements. This must be controlled on regular basis and changed if needed. Every
appliance must be equipped with shut-off valve and quick shut-off valve. Quick shut-off valve must be freely
accessible and within reach of the device. After installation, is necessary to check whether there is a gas leak.
To nd a gas leak you can use soapy water or spray for gas leak detection.
Do not use corrosive substances!! All our appliances are carefully controlled. Gas type, pressure and of the
categories listed named on the technical information plate.
Liquid gas connection:
Pressure for liquid gas connection must be 28 or 30 mbar for propane/butane and 37 mbar for propane. It
is necessary to check the technical label ,gauge the pressure and check the parameters of the nozzle is
installed with the required parameters of the nozzle according to the manufacturer‘s. If the pressure is lower
than 25mbar or higher than 37 mbar, THE APPLIANCE SHALL NOT TO BE CONNECTED.
Gas Connection:
Pressure for methane connection must be 18 or 20 mbar. It is necessary to check the technical label ,gauge
the pressure and check the parameters of the nozzle is installed with the required parameters of the nozzle
according to the manufacturer‘s. If the gas pressure is lower than 15mbar or higher than 22,5 mbar, THE
APPLIANCE SHALL NOT TO BE CONNECTED.
53