3/13/08 2:50 PMDF-50 DIFFUSION? HAZER
Page 3 of 5http://www.reelefx.com/products/df50man.htm
4. If overfilled, empty excess by tipping to the side of the spout and pouring back out. If you have
spilled fluid inside the machine it may be necessary to remove the cover to clean up the excess
fluid. If this is required DISCONNECT the machine from the power supply before opening.
CAUTION
Only Diffusion Fog Fluid may be used in the operation of the DF50. Any other fluid may clog the
machine, create a health hazard, cause damage to the machine and will void the manufacturer’s
warranty coverage.
DO NOT ATTEMPT TO SERVICE THE DF-50
CALL YOUR DEALER IF YOU HAVE ANY QUESTIONS
ROUTINE MAINTENANCE
FLUID LEVEL: Using the glass sight level on the side of the machine fill with a sufficient amount of fluid to
approximately 1/2" below the top level. If you overfill, then tip the machine on its side to dispose of the excess.
COMPRESSOR: No maintenance is required and no attempt should be made to service the compressor. The
compressor is rated at MTBF 5000+ hours before any rebuild may be necessary.
AIR FILTER: Remove top of the black filter element. By twisting counter clockwise 1/4 turn. Remove wool element and
wash in soap and water, then reassemble.
WATER TRAP: To maintain maximum filtering efficiency and to avoid excessive pressure drop, the filter must be kept
clean. To access the filter you need to remove the cover of the DF-50. Turn the drain valve to remove any bowl
accumulation before it reaches level of lower baffle. A visible coating of dirt or condensation on the filter element or
excessive pressure drop indicates cleaning is necessary.
To clean, depressurize air line and remove bowl. Wash filter elements with household soap. Elements should be
replaced if soiled or creating excessive pressure drop. Blow out body with compressed air. Clean bowl only with
household soap.
TANK: No maintenance is required and no attempt should be made to service.
If any problems occur, you should contact your dealer