Storage
DIGIMON is a precision measuring instrument. After use store the manifold in a protected environ-
ment.
Technical description
DIGIMON can be used with the following refrigerants:
R11, R113, R114, R12, R123, R124, R13, R134a, R13B, R22, R227, R23, R290, R401A(Liq), R401A(Vap),
R401B(Liq), R401B(Vap), R402A(Liq), R402A(Vap), R402B(Liq), R402B(Vap), R403B(Liq), R403B(Vap),
R404A, R406A (Liq), R406A(Vap), R407A, R407C(Liq), R407C(Vap), R408A(Liq), R408A(Vap), R409A(Liq),
R409A(Vap), R410A, R413A(Liq), R413A(Vap), R414B, R416A, R417A(Liq), R417A(Vap), R420A,
R422A(Liq), R422A(Vap), R500, R502, R503, R507, R508A, R508B, R600a
Liq = Liquid, Vap = Vapor
Maximum working pressure: Low side
34bar / 500psi / 3400kPa / 3.4MPa
High side
55bar / 800psi / 5500kPa / 5.5MPa
Pressure resolution: 0.01 bar / 0.5 psi / 0.001 MPa / 1 kPa
Pressure units: bar / psi / kPa / MPa
Temperature resolution: 0.5°C / 0.1°F
Vacuum units: mbar / Microns
Power supply: Battery 9Vdc (6F22)
Key function
Power ON / OFF
Vacuum measuring
LCD back light
(switches itself off after 30 sec)
Refrigerant selection up
Refrigerant selection down
Measuring of the Superheat and
Subcool temperature
Enter key function
ON/OFF
VAC
LIGHT
R+
R-
SUPERHEAT/SUBCOOL
ENTER