Reflex Reflexomat RS 150/1 User Manual

Default Icon
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Reflexomat with Touch controller
06.07.2016 - Rev. B
with one compressor:
RS 150/1, RS 300/1, RS 400/1, RS 580/1
with two compressors:
RS 90/2, RS 150/2, RS 300/2, RS 400/2, RS 580/2
GB
Operating manual
Original operating manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Reflex Reflexomat RS 150/1 and is the answer not in the manual?

Reflex Reflexomat RS 150/1 Specifications

General IconGeneral
BrandReflex
ModelReflexomat RS 150/1
CategoryControl Unit
LanguageEnglish

Summary

Safety Guidelines

Intended Use

Defines the device as a pressure maintaining station for heating/cooling water systems with specific water type requirements.

Device Description

Device Functionality

Explains the operational principles of the Reflexomat, including pressure maintenance and water make-up.

Technical Data

Installation Procedures

System Connections

Covers connections to the facility system and external compressed air, with safety precautions.

Water-Side Connection Details

Describes the exemplary water-side connection of the control unit to primary and secondary tanks.

Control Unit Connection Details

Details the connection of the control unit to the primary tank, including compressed air and cable connections.

Fitting the Level Sensor

Provides instructions and standard values for installing the 'LIS' level sensor on the primary tank.

Electrical Connection

Provides safety warnings and general steps for making the electrical connection to the device.

Commissioning Procedures

Determining Minimum Operating Pressure (Po)

Explains how to determine the minimum operating pressure (Po) and its calculation for controller setup.

Modifying Controller Start Routine

Guides the user through the controller's start routine for initial parameter setup during commissioning.

Starting Automatic Mode

Explains how to start the Automatic mode as the conclusion of the initial commissioning process.

Device Operation

Automatic Mode

Details the Automatic mode for continuous operation, including pressure maintenance and make-up functions.

Controller Settings and Operation

Configuring Controller Settings

Details how to adjust system-specific values using the Customer, Default, and Service menus for optimal operation.

Customer Menu Functions

Outlines the customer menu structure and available settings for system-specific value adjustment.

Messages and Faults

Explains how messages are displayed, their causes, and how to acknowledge or reset them.

Maintenance Schedule and Tasks

Checking Switching Points

Provides detailed steps for checking the cut-in/cut-out pressures and make-up activation points.

Disassembly Instructions

Safety Warnings for Disassembly

Provides safety warnings and procedures for safely disassembling the device, covering electrical and pressure risks.