15
TYPICAL BATTERY MANAGEMENT PANEL (inside view)
1
6
2
5
3
Battery Management Panel (Continued)
Above is the battery management panel shown as
an inside view. This view would be facing the star-
board side of the engine.
1. Shown is a 10 amp battery charger. It sup-
plies DC current to assist in keeping the batteries
charged at shore. Be sure to read and understand
the recommendations on how and where to use
the battery charger (see previous pages).
2. These 15 amp fuses protect each of the battery
circuits. If the positive and negative battery cables
are somehow reversed these breakers could trip.
3. The automatic charging relay (ACR) controls the
flow of charge current from the battery charger to
the appropriate battery. The ACR is only used on
the dual battery switch system.
The ACR requires no maintenance and there are
no adjustments since it is a digital component but
check the wires periodically for tightness.