16
Battery Management Panel (Continued)
4. The ground block is a home for a group of neg-
ative (black) wires. You may even find an earth
ground on the block (green). This may be an ad-
ditional ground area for added accessories. Peri-
odically check to ensure all wires are fastened se-
curely. When adding accessories never add more
than 4 connectors to any stud on a ground block.
5. This bank provides a junction for wiring from
the battery charger circuits and from the ACR unit.
Periodically check wires for secure fastening.
6. Battery switch (rear view). See earlier informa-
tion for additional details. Note the red boots on
the rear of the battery switch. Periodically check to
ensure the boots cover the nuts securely and that
the connections and nuts are tight. Disconnect the
battery (ies) positive or + wires before tightening
the battery switch nuts.