City Series CB40E Gas Fireplace
Model CB40E-NG CB40E-LP
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa)
Manifold Pressure - High 3.8” W.C. (0.94 kPa) 10.5” W.C. (2.62 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orice Size -Altitude 0-4500 ft. #42 DMS #53 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
15,500 BTU/h
(4.54 kW)
15,500 BTU/h
(4.54 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
28,500 BTU/h
(8.33 kW)
28,500 BTU/h
(8.33 kW)
Vent Sizing
4” Inner / 6-5/8” Outer 4” Inner / 6-5/8” Outer
48
7
16
"
1231mm
25
9
16
"
648mm
37
3
8
"
949mm
43"
1091mm
33
7
16
"
849mm
7
1
4
"
183mm
Ø
4"
102mm
Ø 6
3
4
"
171mm
11
7
16
"
291mm
24
1
4
"
616mm
49
5
8
"
1261mm
18
11
16
"
475mm
17
11
16
"
449mm
34
5
8
"
879mm
10
1
2
"
267mm
15
1
16
"
382mm
39
5
8
"
1007mm
7
7
8
"
200mm
Question and Answer IconNeed help?

Do you have a question about the Regency City Series CB40E Series and is the answer not in the manual?

Regency City Series CB40E Series Specifications

General IconGeneral
Fuel TypeNatural Gas or Propane
BTU Input (NG)40, 000 BTU
BTU Input (LP)40, 000 BTU
VentingDirect Vent
Ignition SystemElectronic Ignition
FinishBlack
WarrantyLimited Lifetime
Optional FeaturesRemote Control

Related product manuals