12
4. Insert tting into pipe up to the stop. After a brief period, the tting
will sit tightly in the pipe (memory effect).
Note: All sealing ribs must be covered. Until the memory effect has
set in completely, the tting can fall out of the pipe. Make sure to seat
the tting in level position.
6. Start compression process by activating the operating switch and
press in the compression-sleeve up to the tting collar.
CAUTION! Do not touch moving parts. Touching moving parts
could cause ngers to become trapped.
The compression process can be interrupted at any time by releasing
the operating switch.
7. The tool comes equipped with a semi-automatic release valve. If the
tool is moved to its nal position for a prolonged period or used again
after arriving at its nal position, the tool will automatically return to
its starting position. The tool can be manually returned to its starting
position if the release valve is activated using black button opposite
the operating switch.
8. Completed compression-sleeve joint.
5. Fully insert the joint into the clamping tool.
Note: Do not tilt. Tool must be applied over full surface and at right
angles.