14
RAUTOOL A-LIGHT2
MAINTENANCE
Regular Inspection Repairs
Note: Always remove the battery or unplug from the mains before
cleaning and inspection.
– Always keep jaw sets, expanding tools and cylinders clean. When
soiled, clean them with a brush and oil them. Then store the tool in
a dry place.
– Before every use, check the jaw sets, expanding tools and the
A-light2 basic tool for damage or visible wear. Damaged tools must
not be used anymore and should immediately be sent to your local
REHAU representative for repair.
– Make sure that the jaw sets are fully applied across the entire
surface and at a right angle during the compression process. The
compression sleeve should be inserted up to the tting collar.
– Regularly grease the expanding tool taper. Do not apply grease to
the surface of expander segments. Should excess grease reach the
expander segments, the segments must be thoroughly cleaned with
cleaning solvent and then dried.
Note: Do not perform any repairs on the tool yourself. Return the tool
to your local REHAU representative.
Storage
Never store the tool if wet. Dry the tool and grease it. Then store it in
a dry place.
Store the tool in its nal position (extended cylinder or jaw sets) to
extend its service life.