Do you have a question about the Reimers RB Series and is the answer not in the manual?
Lists standard components included with each boiler model.
Specifies the duration of the warranty for components.
Outlines conditions and restrictions for the warranty coverage.
Details the process for making warranty claims and obtaining repairs.
States the company's liability for indirect damages.
Instructions for maintaining and replacing the gauge glass protector.
Warning against altering or improperly using the pressure tank.
Advice to check state and city requirements for boiler registration.
Guidance for qualified personnel performing installation and repair work.
Instructions for testing the safety valve and ensuring safe discharge.
Requirements for steam piping material and installation expertise.
Explains the necessity and frequency of boiler blowdown for maintenance.
Guidelines for placing the boiler in a suitable and accessible location.
Specifies minimum clearance requirements around the boiler for safety and access.
Provides decoding for boiler nameplate ratings related to installation clearances.
Lists recommended water properties and treatment for boiler feed water.
Wiring instructions for three-phase models without an extension box.
Step-by-step guide for safely starting up the boiler.
Explains the low water cutoff safety feature and its operation.
Describes the high pressure cutoff mechanism to prevent over-pressurization.
Details the safety feature that stops refilling at high water levels.
Explains the automatic process for maintaining boiler water levels.
Describes the optional automatic blowoff feature.
Explains optional remote control and status monitoring features.
Instructions for periodic blowdown to remove sediment and scale.
Procedure for monthly testing of the safety valve.
Steps for testing the high limit pressure control's functionality.
Procedure for testing the low water cutoff controller's operation.
Maintenance for water level probes and baffle box to ensure accurate readings.
Table correlating boiler status indicators with troubleshooting steps.
Steps to start up the condensate return system.
Maintenance procedures for the condensate return system strainer and gauge glass.
| Operating Pressure | Up to 150 psi |
|---|---|
| Fuel Type | Electric |
| Construction | ASME code construction |
| Water Content | Varies by model |
| Flue Gas Temperature | Not applicable (electric) |
| Weight | Varies by model, see product data |
| Voltage | 208V, 240V, 480V, 600V |
| Heating Capacity | 30, 700 BTU/hr - 7, 370, 000 BTU/hr |