EasyManua.ls Logo

Reliable i300 - System Information and Specifications; Water Usage and Component Identification; Technical Data and Specifications

Reliable i300
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
06
Pourtheremainingsolutionoutofthetank.Youmayseebitsofsedimentand
mineral come out at this point.
4. Rinse the tank with clean water until there is no smell of vinegar or any sedi-
ment bits coming from inside the tank. NOTE: Sediment/mineral pieces can
be blown into the solenoid valve or the steam nozzle during operation so it is
important that they are not left in the tank after cleaning.
5. The unit is now ready for use.
WATER INSTRUCTIONS
Use tap water or 50/50 tap/distilled water in the appliance. Do not use perfume
or products containing alcohol in the appliance.
DESCRIPTION OF THE IRON STATION
1. Safety cap
2. Wand to hold mono-hose up
3. Iron button
4. Boiler button
5. Lightforlowwater
6. Temperature regulating knob
7. Steam button
8. Thermostat reset button
TECHNICAL DATA
Adjustableironthermostatsetfrom60°Cto215°C
Bimetallicsafetyironthermostatwithmanualresetat275°C
Full aluminium-plated heating element at 800W – 120V
Boiler power i300: 700W
Working pressure i300: 2,5 bar
Tank nominal capacity of model i300: 1.4 litres

Other manuals for Reliable i300

Related product manuals