2 REMCO INDUSTRIES | ProFlo Owner’s Manual | www.remcoindustries.com | 763-253-4740
763-253-4740 | www.remcoindustries.com | ProFlo Owner’s Manual | REMCO INDUSTRIES 3
Please read these Operational and Installation Guidelines before
installing the ProFlo™ Series Pumps. If additional help is needed,
please consult the Factory.
CAUTIONS
• Waterpipeconnectionsandxturesdirectlyconnectedtoa
potable water supply shall be sized, installed and maintained
in accordance with Federal, State, and local codes.
• Donotoperatethepumpabovethepressurelimitations
speciedonthedatalabel.
• Neveroperatethepumpinaharshenvironmentorhazardous
atmosphere, since motor brush and switch may cause
electrical arcing.
• Do not pump gasoline or other flammable liquids.
Pump head materials are designed for use with water
only. Do not use with petroleum products.
• Do not assume fluid compatibility. If the fluid is
improperly matched to the pumps’ elastomers,
a leak may occur
• Aslongasthereisinletwaterpressure,thepumpwillnotstop
forward flow of water even if the motor is turned off. Be sure
the system has positive means of shutting off water supply.
• Alwaysconsiderelectricalshockhazardwhenworkingwith
and handling electrical equipment. If uncertain, consult
an Electrician. Electrical wiring should only be done by a
qualiedElectricianperLocalandStateElectricalCodes.
MOUNTING
• Thepumpshouldbemountedinadryplaceandaway
from any source of heat. If an enclosure is used, special
instructions for cooling the motor may be necessary. Consult
the Factory.
• Donotsubjectthepumptoextremehighorlow(freezing)
temperatureswhileinoperation.(Operatingambient
temperaturerangeis32ºFto115ºF).
• Thepumpmaybemountedhorizontallywiththeoutletport
on the right when viewed from the pump end or with the
pump above the mount; or vertically with the pump above
or below the motor.
PLUMBING
• Thepumpisequippedwitheitherapressuresensing
demand switch, a bypass relief valve, or both which controls
themaximumsafeoperatingpressure.
• Werecommenduseofexibletubingwithproper
pressure rating.
• Pumpwillprimeonlyifallpressureisrelievedfromoutletport.
• Itisrecommendedthatdebris-freewaterbepumpedoran
in-linesedimentlter(100mesh)beinstalledattheinletside
tokeepforeigndebrisoutofthesystem.
• Thepumpshouldalwaysbemountedpriortoany
components which could introduce particles to the water;
thus, preventing them from entering the pump chambers and
possibly causing clogging.
• Avoidanysharpbendswhichmaycrimptubingandrestrict
ow.Use90ºelbowttingsifnecessary.REMCOprovides
pumpswithdifferentkindsofttings.PleaseconsultFactory
for your needs.
ELECTRICAL
• TheProFlo™SeriesPumpsaredesignedforintermittentduty,
but may run continuously if the motor temperature does not
exceedtherecommendedlimit.SomeProFlo™SeriesPumps
are equipped with thermally protected motors and in case
motortemperatureexceedsthermalcut-outrating,pump
will shut down and will not restart until motor cools down to
speciedtemperature.PleaseconsulttheappropriateData
Sheet for continuous running parameters, noting the effect
ofrapidOn/OffCycling(paragraph9,page2).
• Ifapowersupplyisusedwiththesystemandthesupply
is not furnished by REMCO, it will need to be reviewed for
correct application and approval by REMCO.
Operational and Installation Guidelines
Please read this Owner’s Manual completely before using this
pump.Assemble,test,anduseonlyinaccordancewiththe
Owner’s Manual instructions.
READandFOLLOWchemicalsafetyinstructions.Pesticides
are hazardous chemicals.
KNOW emergency procedures BEFORE handling chemicals.
Pumpleaks,bodilychemicalcontact,poisoning,andspills
require immediate response.
AVOIDinhaling,ingesting,orcomingintocontactwithany
chemicals.
WEARpersonalprotectivegearwhenoperating,cleaning,and
servicing the pump.
KEEP pump and spray materials away from children and pets.
Pesticidesareespeciallytoxictothem.
DO NOT TURN ON POWER to pump until ready to spray
in order to avoid unintentional spray release.
Improper use of the pump or handling of chemicals could result
inseriousinjuryorillnesstotheoperatorornearbypersons/
animals, or could cause damage to the environment.
Operational and Installation Warnings
ProFlo
3300 | 5500 | FatBoy
®
ProFlo
3300 | 5500 | FatBoy
®
NOTE
This pump is recommended for use in spraying non-flammable liquids such as pesticides, water for plants/trees or dust control, ice
controlchemicals,orwater-basednon-ammablesealantsorstainsforoutdoorwoodsurfaces.However,WERECOMMENDTHAT
THEPUMPSNOTBEUSEDFOROTHERPURPOSESONCEITHASBEENUSEDFORSPRAYINGPESTICIDES.
Anychemicalwillleavesomeresidualinthepump,evenafterthepumphasbeenproperlycleaned.Theseresidualchemicalscan
haveunexpectedeffectsonfutureuses.Forexample,sprayingwaterorotherliquidsthatarecontaminatedwithresidualpesticide
may result in unforeseen hazards to plant or animal life.
Troubleshooting Guidelines
IF PUMP WILL NOT START CHECK
• Correctvoltage(±10%)andelectricalconnections
• Fuseorbreaker
• Pressureswitchoperationandcorrectvoltageatswitch
• Rectierormotorforopenorgroundedcircuit
• Lockeddriveassembly.
IF PUMP WILL NOT PRIME (NO DISCHARGE WITH
MOTOR RUNNING) CHECK
• Debrisinstrainer
• Restriction(kinks)ininlet/outlettubes
• Debrisorswellingininlet/outletvalves
• Airleakinginfrominlet
IF PUMP WILL NOT SHUT OFF (OUTPUT LINE CLOSED
AND NO LEADS) CHECK
• Airtrappedinoutletlineorpumphead
• Correctvoltagetopump
• Debrisinpumpinlet/outletvalves
• Loosedriveassemblyorpumpheadscrews
• Pressureswitchoperations/adjustments
• Leaks
IF PUMP LEAKS FROM PUMP HEAD
OR SWITCH CHECK:
• Loosescrewsatswitchorpumphead
• Switchdiaphragmrupturedorpinched
• Punctureddiaphragmifuidispresent
The basic demand pump is controlled by a built-in pressure
sensing demand switch. When a faucet or valve is opened
down stream of the pump, line pressure drops, thus starting
the pump automatically. Conversely, when the valve shuts,
the line pressure increases turning the pump off automatically.
The pressure switch actuates in response to the pump outlet
pressure at a predetermined and preset pressure. The pump
label indicates the pre-set OFF pressures. Typically, the OFF
pressureisaccuratelysetattheFACTORYandtheONpressure
is within an allowable range below that value. In response to
the characteristics of the system in which the pump is installed,
suchastheexibilityandlengthofthetubing,andthefaucet
or valves and the duration that they are open, these pressure
settings may vary. Therefore, change in pressure settings is
expectedwithuseandovertime.
If the pump does not have an integral pressure sensing demand
switch(i.e.pumpisoperatedwithanexternalcontrol),pumpwill
beequippedwithabypassreliefvalve(bypassisfactorypreset).
Read the OPERATIONAL AND INSTALLATION GUIDELINES
on the other side carefully before starting to install the
pump. Consult the Factory if there is any question.
Determine the optimum location for your pump before
proceeding.
• Turnofftheuidsupply.
• Cuttheexibletubinginsufcientlengthtoavoidanystress
on the tubing or hose where it connects to the pump or the
ttingonanyaccessoryorhose.
• Inserttubingorhoseintopumpports.Ifcompressionttings
with threaded nuts are used, insert tubing until it bottoms out
in the port and hand tighten the compression nut until the
connection is tight. Then use a wrench to tighten the nut 1/2
turnclockwiseorfollowthewrenchtighteninginstructions
providedbythettingmanufacturer.
• TheProFlo
Series pump is now ready for operation. Open
the inlet valve if any to allow fluid to flow to the pump.
• Ifthepowersourceisatransformer,plugtheappropriate
REMCO supplied or approved transformer into the receptacle
and connect the pump to the transformer. If the power source
is not a transformer, connect the pump to the appropriate
powersource.Openthedischargeordispensingvalve.Allow
water to circulate, purging any entrapped air.
• Thepumpwillnowstartbuildingpressure.Operating
pressure will vary with flow rate, flow valve, feed-water
pressureandlinevoltage.Checkforttingleaks.
• Ifcompressionttingswiththreadednutsareused,observe
anyleaksafterpumphasrunforapproximately15minutes.
Furthertightencompressionnutsapproximately1/8to1/4of
aturnonallttingsinthesystem.Wait15minutesandrepeat
theleakcheck.
NOTE: Further adjustments should not be necessary
although it may take several days of operation before
all the air has been purged and the system is stabilized.
• RapidOn/OffCyclingmustbelimitedtonomorethan6times
per minute, even if the pump is operating in the Continuous
Duty zone. Cycling could cause the motor to heat beyond
therecommendedmaximumtemperature,andreducethe
operational life of the pump and pressure-sensing switch.
Installation Procedure
Servicing
EVERY YEAR
Checksystemagainstoperatingstandards.Ifcontinuousduty,replacelowerhousingassembly
EVERY OTHER YEAR
Checkagainstoperatingstandards.Ifcontinuousduty,replacemotor
EVERY FIFTH YEAR
Replace valves