11
Technical Data
Any mode of operation other than specified in these operating instructions is not permissible!
Failing to observe it causes the customer to lose all rights to guarantee or damage claims.
Any claims under guarantee regarding materials can be accepted only when the orderer or his customer has
filled in completely the “guarantee certificate” which is enclosed with every REMKO-device and has
returned it to REMKO GmbH & Co. KG in due time after the unit’s sale and commissioning.
Model AMT 60-E AMT 90-E
Working range - temperature °C 3 - 32 3 - 32
Working range - humidity % r.h. 40 - 100 40 - 100
Dehumidifying capacity, max. l/day 64 93
Dehumidifying capacity at 30°C / 80% r.h l/day 54,2 79,8
Dehumidifying capacity at 20°C / 70% r.h. l/day 34,9 43,1
Dehumidifying capacity at 10°C / 60% r.h. l/day 11,3 16,3
Capacity water container litres 7,5 –––––
Cooling capacity at 5°C t
v
/ 45°C t
k
kW 2,86 4,36
Air volume m³/h 765 1050
Refrigerant (FCKW -free) R 407 C R 407 C
Refrigerant quantity g 575 1600
Power supply 1~ V 230 230
Frequency Hz 50 50
Rated current consumption, max. A 4,1 6,9
Power consumption, max. kW 0,94 1,56
Power consumption at 20°C / 70% r.F. kW 0,691 0,978
Fuse protection (required) A 10 16
Sound pressure level L
pA
1m
1)
dB (A) 60 68
Dimensions total depth mm 720 (635) 700 (630)
total width mm 590 740
total height mm 880 (720) 970 (855)
Weight kg 48 63
1) Noise measuring DIN 45635 - 13 - KL 3
( ) Dimensions without transport handle